摘要
目的观察8种增/溶剂对Ames试验致突变性检出的影响,为合理选用增/溶剂提供参考。方法依照《化妆品卫生规范》(2007)中鼠伤寒沙门氏菌/回复突变试验方法,对95%乙醇、甲醇、丙酮、吐温-20、吐温-60、吐温-80、DMSO和乙酸乙酯8种增/溶剂进行测定和结果判定。结果吐温-20在不大于5.0mg/皿剂量下,其余7种增/溶剂在最大剂量100.0 mg/皿情况下对TA97、TA98、TA100和TA102菌株的回变菌落数对比判定均显阴性。结论 Ames试验中,95%乙醇、甲醇、丙酮、吐温-60、吐温-80、DMSO和乙酸乙酯最大使用剂量可为100.0 mg/皿;吐温-20最大使用剂量为5.0 mg/皿。
Objectives To observe the effect of 8 Ames Test to provide reference for reasonable selection solubilizers/solvents on the detection of mutagenicity in of solubilizers/solvents. Methods Reverse mutation of Salmonella typhimurium test was used for testing the mutagenic effect of 8 solubilizers/solvents, including 95% ethanol, methanol, acetone, tween -20, tween -60, tween -80, DMSO and ethyl acetate on the results implemented according to the Ames Tests method in the Hygienic Standard for Cosmetics (2007). Results Under the concentrations of not more than 5.0 mg/petri dish for tween - 20, and the maximum dose of 100.0 mg/petri dish for other 7 solubilizers/solvents, the comparative judgement of revertant colonies of TA97, TA98, TAI00 and TA102 strains were negative. Conclusion As the maximum dose, 100.0 mg/petri dish for 95% ethanol, methanol, acetone, tween- 60, tween -80, DMSO and ethyl acetate, and not more than 5.0 mg/petri dish for tween -20 could be used in Ames Test.
出处
《环境卫生学杂志》
北大核心
2012年第3期105-107,共3页
JOURNAL OF ENVIRONMENTAL HYGIENE