采用宙斯麻醉机自动控制系统全紧闭麻醉七氟醚的消耗 被引量:3

The Sevoflurane Consumption in All Closed Anesthetic with Automatic Control System of Zeus Anesthesia Machine
下载PDF
导出
摘要 目的本研究旨在研究采用宙斯(ZEUS)麻醉机自动控制系统全紧闭麻醉七氟醚的消耗。方法腹部外科手术病人60例,快速诱导、气管插管,实验组接宙斯(ZEUS)麻醉机全紧闭麻醉模式,设置呼出七氟醚浓度为1.5,通过调整,控制1.3MAC;对照组接Fabius GS麻醉机,氧流量2.0 L/min,3%七氟醚吸入,达到1.3MAC时,氧流量减至1.0 L/min,减小挥发灌刻度,控制在1.3MAC。分别记录吸入期(0~4 min)和维持期(4~64 min)两组七氟醚消耗量。结果实验组在吸入期七氟醚的消耗较对照组显著缩短(P<0.05),在维持期七氟醚的消耗与对照组比较有极显著差异(P<0.01)。结论采用宙斯麻醉机自动控制系统全紧闭麻醉能使七氟醚的消耗大幅减少。 Objective To study the Sevoflurane consumption in all closed anesthetic with Automatic control system of Zeus anesthesia machine. Methods 60 cases of abdominal surgery patients, rapid induction, endotracheal intubation. The experimental group of Zeus (the ZEUS) anesthesia machine, the whole closed anesthetic mode, the set exhaled sevoflurane concentrations of 1.5, by adjusting the control 1.3 MAC. The control group received the Fabius GS anesthesia machines, oxygen flow 2. 0 L/min, 3% sevoflurane wash into the reach of 1.3MAC reduce the oxygen flow to 1.0 L/min reduce volatile irrigation scale control in 1.3MAC. The two groups were recorded sevoflurane consumption during wash entry period (0 -4 min) and maintenance phase (4 - 64 min). Results The experimental group in the wash entry sevoflurane consumption than the control group was significantly shorter ( P 〈 0. 05 ). During the maintenance phase, the consumption of sevoflurane compared with control group there was a significant difference (P 〈 0. 01 ). Conclusion Application of the closed anesthesia with automatic control system of Zeus anesthesia machine can reduced sevoflurane consumption substantially.
出处 《黑龙江医学》 2012年第2期98-99,共2页 Heilongjiang Medical Journal
关键词 自动控制 全紧闭麻醉 七氟醚 消耗 Automatic control Full shut anesthesia Sevoflurane Consumption
  • 相关文献

参考文献3

二级参考文献12

  • 1王立萍,郑方,李恩有,刘淑杰,李文志,韩非.七氟醚和地氟醚紧闭循环麻醉下神经外科手术后病人肾功能的变化[J].中华麻醉学杂志,2005,25(9):657-659. 被引量:16
  • 2Keijzer C, Perez RS, De Lange JJ. Carbon monoxide production from five volatile anesthetics in dry sodalime in a patient model: halothane and sevoflurane do produce carbon monoxide;temperature is a poor predictor of carbon monoxide production. BMC Anesthesiol, 2005,5 : 6. 被引量:1
  • 3Wallin RF,Regan BM, Napoli MD, et al. Sevoflurane: a new inhalational anesthetic agent. Anesth Analg, 1975,54 :758-766. 被引量:1
  • 4William P. Arnold III,Dorre Nicholau. Environmental Safety Including Chemical Dependency//Miller RD, eds. Miller' s Anesthesia. 6th ed. New York: Churchill Livingstone, 2005: 3159-3161. 被引量:1
  • 5Weir HM, Kennedy RR. Infusing liquid anaesthetics into a closed circuit. Anaesth Intensive Care, 1994, 22 : 376-379. 被引量:1
  • 6Dorsch JA, Dorsch SE. Controlling trace gas levels//Dorsch JA, Dorsch SE, eds. Understanding anesthesia equipment:construction, care and complications. 3rd ed. Baltimore. Williams & Wilkins, 1994 : 281. 被引量:1
  • 7Keller KA, Callan C, Prokocimer P, et al. Inhalation toxicity study of a haloalkene degradant of sevoflurane, Compound A ( PIFE), in SpragueDawley rats. Anesthesiology, 1995,83:1220-1232. 被引量:1
  • 8Gentz BA, Malan TP Jr. Renal toxicity with sevoflurane: a storm in a teacup? Drugs,2001,61:2155-2162. 被引量:1
  • 9Kharasch ED,Frink EJ Jr, Zager R,et al. Assessment of low-flow sevoflurane and isoflurane effects on renal function using sensitive markers of tubular toxicity. Anesthesiology, 1997,86:1238-1253. 被引量:1
  • 10Kharasch ED, Frink EJ Jr, Artru A, et al. Long-duration low-flow sevoflurane and isoflurane effects on postoperative renal and hepatic function. Anesth Analg,2001,93:1511-1520. 被引量:1