期刊文献+

128层螺旋CT心脏冠状动脉成像中优化扫描参数的研究

Optimization of Scanning Parameters in 128-slice CT Coronary Artery Imaging
下载PDF
导出
摘要 目的:对128层螺旋CT在心脏冠状动脉成像中扫描参数进行探究。方法:选取2010—2011年在我院进行心脏冠状动脉扫描的患者150名,根据患者心率不同将其分为4组,分别选择单扇区SSEG扫描,SSEG扫描,双扇区SSB扫描,SSB扫描模式。患者进行128层螺旋CT扫描。扫描结果由资深影像科医师在完全不知情的情况下根据心率与扇区选择对成像质量进行评分,然后将不同扫描模式评分进行对比。结果:84例SSEG扫描模式中16例低于推荐螺距值,60例自动选择与推荐螺距值结果一致;因此心率越快,对比剂所需的用量越少;不同心率和扇区图像成像质量差异明显,对于心率70次以上应使用SSB扫描。结论:128层螺旋CT选择适当的对比剂量和参数时,应根据心率调节螺距值以及进行扇形区的选择等多方面参数,这是增加成功率、保证获得高质量图像的前提。 Objective:To explore the function of 128-slice CT scanning in the coronary angiograph.Methods:Rommandly select 150 patients in our section with coronary angiograph from 2010 to 2011.Based on the difenece of the heart rate,divide the cases to 4 group,which include SSEG single scanning mode,SSEG scanning mode,SSB scanning mode,SSB double scanning.Results:In 84 case of SSEG scanning mode,the pitch value of 16 cases were lower than the recommended pitch value,and that of the 60 case was according with the recommended pitch value.We can conclude that,faster the heart rate,less the required contrast dosage.There was a significant difference between the quality of the different heart rate and different sectors.Conclusion:128-slice spiral CT scanning play a impotant role in the coronary angiograph.
作者 黄葵
出处 《亚太传统医药》 2012年第2期151-153,共3页 Asia-Pacific Traditional Medicine
基金 佛山市卫生局医学科研立项课题(2011459)
关键词 128层螺旋CT 冠脉成像 优化扫描参数 128-slice CT Coronary Imaging Optimization of Scanning Parameters
  • 相关文献

参考文献4

二级参考文献20

  • 1潘爱珍,甘毅,罗灿华,陈涛,郑建忠.16排CT用于腹主动脉及下肢动脉阻塞性病变的成像研究[J].中国医学影像技术,2004,20(6):898-900. 被引量:27
  • 2沈君,李国照,梁碧玲,洪国斌,周翠屏,王景峰,聂如琼,曾伟科,李洁婷.心电图编辑功能在64层螺旋CT冠状动脉成像中的初步应用[J].中国医学影像技术,2007,23(4):516-519. 被引量:20
  • 3Nieman K, Rensing BJ, van Geuns R J, et al. Non-invasive coronary angiography with muhislice spiral computed tomography: impact of heart rate. Heart ,2002,88:470-474. 被引量:1
  • 4Flohr TG, McCollough CH, Bruder H, et al. First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol, 2006, 16:256-268. 被引量:1
  • 5Austen WG, Edwards JE, Frye RL, et al. A reporting system on patients evaluated for coronary artery disease: Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council Cardiovascular Surgery, American Heart Association. Circulation, 1975, 51 (4 Suppl) : 5-40. 被引量:1
  • 6Seheffel H, Alkadhi H, Plass A, et al. Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control. Eur Radiol, 2006, 16:2739-2747. 被引量:1
  • 7Achenbach S, Ropers D, HoUe J, et al. In-plane coronary arterial motion velocity: measurement with electron-beam CT. Radiology, 2000, 216:457-463. 被引量:1
  • 8Dewey M, Laule M, Krug L, et al. Multisegment and halfscan reconstruction of 16-slice computed tomography for detection of coronary artery stenoses. Invest Radiol, 2004, 39:223-229. 被引量:1
  • 9Halliburton sS, Stillman AE, Flohr T, et al. Do segmented reconstruction algorithms for cardiac multi-slice computed tomography improve image quality? Herz, 2003, 28:20-31. 被引量:1
  • 10Cademartiri F, Mollet NR, Runza G, et al. Improving diagnostic accuracy of MDCT coronary angiography in patients with mild heart rhythm irregularities using ECG editing. AIR, 2006, 186: 634-638. 被引量:1

共引文献41