期刊文献+

40层螺旋CT冠状动脉成像方法的探讨

Study on the Method of Coronary Arteries with 40-slices Spiral CT
下载PDF
导出
摘要 目的探讨40层螺旋CT冠状动脉的成像方法。资料与方法应用40层螺旋CT进行冠状动脉成像,将113例患者分为两组,一组心率<75次/min(90例),另一组心率≥75次/min(23例),将对比剂追踪自动触发感兴趣区(ROI)分别设定在肺动脉主干平面的升主动脉段和降主动脉段,探讨最佳冠状动脉成像的方法。结果将ROI设置在肺动脉平面主干的降主动脉比升主动脉能获得更好的冠状动脉图像。结论40层螺旋CT对心率<75次/min、选择肺动脉主干平面的降主动脉段作为对比剂追踪自动触发ROI,能够获得高质量的冠状动脉图像。 Objective To discuss the method of coronary arteries with 40 slices spiral CT. Materials and Methods 113 patients were randomly assigned into two group, all patients were examined with 40 slices spiral CT. ROI was set in AAO and DAO, heart rote was controlled properly. Results High quality image of coronary arteries was obtained when heart rate was controllcd properly and ROI was set in AAO and DAO. Conclusion The coronary artery segments would be better visualized with heart rate 〈 75bpm and set ROI at DAO with 40 slices spiral CT.
出处 《临床放射学杂志》 CSCD 北大核心 2007年第1期70-72,共3页 Journal of Clinical Radiology
关键词 体层摄影术 X线计算机 冠状动脉造影术 Angioeardiography Tomography, X-ray computed
  • 相关文献

参考文献5

二级参考文献20

  • 1何茜,张龙江,宋光义,杨彦荣,包颜明,王克超,杨亚英.层厚和螺距对多层面螺旋CT冠状动脉成像图像质量的影响:离体猪心的实验研究[J].中国临床医学影像杂志,2002,13(S1):51-53. 被引量:1
  • 2潘爱珍,甘毅,罗灿华,陈涛,郑建忠.16排CT用于腹主动脉及下肢动脉阻塞性病变的成像研究[J].中国医学影像技术,2004,20(6):898-900. 被引量:27
  • 3Achenbach S, Ulzheimer S, Baum U,et al. Noninvasive coronary angiography by retrospectively ECG-gated mutislice spiral CT. Circulation, 2000, 102:2823 被引量:1
  • 4Nieman K, Rensing B, van Geuns RM,et al. Usefulness of mutislices computed tomography for detecting obstructive coronary artery disease. Am J Cardiol, 2002, 89:913 被引量:1
  • 5Achenbach S, Giesler T, Ropers D, et al. Detection of coronary artery stenoses by contrast-enhanced, retrospectively electrocardiographically-gated, multislice spiral computed tomography[J]. Circulation, 2001,103(21):2535-2538. 被引量:1
  • 6Nieman K, oudkerk M, Rensing BJ, et al. Coronary angiography with multi-slice computed tomography[J]. Lancet, 2001, 357(9256):599-603. 被引量:1
  • 7Giesler T, Baum U, Ropers D, et al. Noninvasive visualization of coronary arteries using contrastenhanced multidetector CT: influence of heart rate on image quality and stenosis detection[J]. AJR, 2002, 179(4):911-916. 被引量:1
  • 8Achenbach S, Ropers D, Holle J, et al. In-plane coronary arterial motion velocity: measurement with electron beam CT[J]. Radioilgy,2000,216(2):457-463. 被引量:1
  • 9Achenbach S, Ulzheimer S, Baum U, et al. Noninvasive coronary angiography by retrospectively ECG-gated multislice spiral CT[J]. Circulation,2000, 102(23):2823-2828. 被引量:1
  • 10Kopp AF, Schroeder S, Kuettner A, et al. Coronary arteries: retrospectively ECG-gated multidetector row CT angiography with selective optimization of the image reconstruction window[J]. Radiology, 2001, 221(3):683-688. 被引量:1

共引文献58

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部