摘要
介绍了河北大唐国际王滩发电有限责任公司2×600 MW机组石灰石-石膏湿法烟气脱硫系统运行优化的经验,给出了运行优化的具体措施。通过试验和统计分析,得出了脱硫系统的较佳运行方式。
The experiences of operation optimization of limestone-gypsum wet FGD system of 2×600 MW unit in Hebei Datang International Wangtan Power Generation Company Limited were introduced.The concrete measures of operation optimization were given.Based on experiment and the statistical analysis,the better operation mode of desulphurization system was obtained.
出处
《华电技术》
CAS
2011年第9期72-76,98,共5页
HUADIAN TECHNOLOGY
关键词
湿法烟气脱硫
运行优化
试验
wet flue gas desulphurization(wet FDG,WFGD)
operation optimization
experiment