摘要
对屏式过热器管进行了宏观检查、金相显微组织观察和分析以及拉伸性能测试。结果表明,该屏式过热器管失效的主要原因是长时超温与短时超温共同作用的结果。
The macro-examination of superheater tube,metallographic observation and microstructure analysis were carried out,and the mechanical properties were tested.The results show that: the main reasons for the platen superheater tube failure are the inter-action results of long-time over temperature and short-time over temperature.
出处
《热加工工艺》
CSCD
北大核心
2011年第4期184-185,189,共3页
Hot Working Technology
关键词
长时超温
短时超温
过热器管
金相组织
long-time over temperature
short-time over temperature
superheater tube
microstructure