期刊文献+

高压电场放电装置产生的等离子体对不同基材的消毒研究 被引量:2

STUDY ON DISINFECTION EFFECT OF THE ATMOSPHERIC PRESSURE PLASMA FROM HIGH VOLTAGE ELECTRIC FIELD DISCHARGE DEVICE ON DIFFERENT SUBSTRATES
原文传递
导出
摘要 目的利用大气压下高压电场放电装置产生的等离子体对三种不同基材的消毒研究。方法采用载体定量杀菌试验方法,对该装置杀灭物体表面细菌的效果进行了观察。结果该装置产生的等离子体作用5 min,对玻璃器皿表面上污染的枯草杆菌繁殖体达到完全杀灭;对污染在内径1 mm塑料管内的枯草杆菌繁殖体作用30 min,平均杀灭对数值仅0.5。用该装置产生的等离子体作用30 min,可使麦粉和番茄片中细菌数降低到卫生部门允许的最低标准。结论该大气压下高压电场放电等离子体对光滑物体表面上细菌杀灭效果较好,对管腔内细菌杀灭作用较差。 Objective To study the disinfection effect of the atmospheric pressure plasma from high voltage electric field discharge device on three different substrates.Methods Carrier quantitative bactericidal test was used to observe disinfection effect on the object surface of the device.Results The device could completely kill the Bacillus subtilis vegetative on the surface of glass after 5 min treatment.While the killing logarithm value of the Bacillus subtilis vegetative in PTFT capillary after 30 min treatment of this device was 0.5.Bacteria in the barley grass powder or tomato slice also could be reduced to the minimum standards allowed of the health sector after 30 min treatment.Conclusion The atmospheric pressure plasma from high voltage electric field device has a good disinfection effect on the bacteria on the smooth surface while has an unsatisfactory disinfection effect on the bacteria in the capillary.
出处 《中国消毒学杂志》 CAS 2010年第5期557-560,共4页 Chinese Journal of Disinfection
关键词 大气压等离子体 干食品 消毒 机理 atmospheric pressure plasma dry food product disinfection mechanism
  • 相关文献

参考文献9

  • 1Laroussi M. Nonthermal decontamination of biological media by atmospheric pressure plasmas : review, analysis, and prospects[ J ]. Plasma Sci, 2002 : 30 ( 12 ) : 1409. 被引量:1
  • 2Amypruden A. Bacterial Inactivation in open air by the afterglow plume emitted from a grounded hollow slot electrode[ J]. Environ. Sci. Technol,2005:39(3) :339. 被引量:1
  • 3Li Guo, Li He - ping. Genetic effects of radio - frequency, atmospheric pressure glow discharges with helium [ J ]. Appl. Phys. Lett ,2008,92 (2) :221. 被引量:1
  • 4Gweon B ,Kim DB. Eseherichia coli deactivation study controlling the atmospheric pressure plasma discharge conditions[ J]. Current Applied Physics,2009,9 (6) :625. 被引量:1
  • 5姜玉,秦克勤,张善端,朱绍龙,张源,邓续周,宋伟民.大气压辉光放电等离子体对不同细菌杀灭效果的研究[J].中国消毒学杂志,2007,24(1):1-3. 被引量:12
  • 6魏丽萍.中国强制性国家标准汇编(食品卷1)[M].北京:中国标准出版社,2003:357. 被引量:1
  • 7Gadria RB, Roth JR. Sterilization and plasma processing of room temperature surfaces with a one atmosphere uniform glow discharge plasma[J]. Surf Coat Technol, 2000,131 (5) :528. 被引量:1
  • 8Pears RW, Gaydon AG. The Identification of molecular spectra 4th ed[M], london : Chapman & Hall,1976: 263. 被引量:1
  • 9Roth JR. Industrial plasma engineering volume 2: Applications to nothhermal plasma processing[ M]. Londan : Institute of Physics, 2001 : 37. 被引量:1

二级参考文献1

  • 1Wintenberg KK,Hodge A,Montie TC.Use of a one atmosphere uniform glow discharge plasma to kill a broad spectrum of microorganisms[J].J.Vac.Sci.Technol.A.1999;17(4):1539 被引量:1

共引文献11

同被引文献17

  • 1姜玉,秦克勤,张善端,朱绍龙,张源,邓续周,宋伟民.大气压辉光放电等离子体对不同细菌杀灭效果的研究[J].中国消毒学杂志,2007,24(1):1-3. 被引量:12
  • 2姜玉,秦克勤,张善端,宋伟民.大气压辉光放电等离子体消毒效果影响因素[J].中国消毒学杂志,2007,24(2):109-111. 被引量:6
  • 3Atanassova V, Meindl A, Ring C. Prevalence of Staphylococcus aureus and Staphylococcal enterotoxins in raw pork and uncooked smoked ham - a comparison of classical culturing detection and RFLP - PCR [ J ]. Int J Food Mierobiol, 2001,68 ( 1 ) : 105 - 113. 被引量:1
  • 4Bean NH, Goulding JS, Lao C,et al. Surveillance for foodbome - disease outbreaks - United States, 1988 - 1992 [ J]. Morb Mor- tal,1996,45(5) : 1 -66. 被引量:1
  • 5Lowy FD. Staphylococcus aureus infections [ J ]. N Engl J Med, 1998,339 : 520 - 532. 被引量:1
  • 6Hofmann JO, Knoll M, Durr M, et al. Comparison of low - tem- perature hydrogen peroxide gas plasma sterilization for endoscopes using various sterradtrade mark models[ J]. J Hosp Infect,2005, 59(4) :280 -285. 被引量:1
  • 7Lerouge S, Wertheimer M, Tabrizian R, et al. Effect of gas com- position on spore mortality and etching during low - pressure plasmasterilization [ J]. Biomed Mater Res ,2000,51 ( 1 ) : 128 - 135. 被引量:1
  • 8Pintassilgo CD, Kutasi K, Loureiro J. Modelling of a low - pres- sure N2 - 02 discharge and post - discharge reactor for plasma sterilization[ J ]. Plasma Sources Scieneeand Technology, 2007, 16(1) : 115 -122. 被引量:1
  • 9Yardimei O, Setlow P. Plasma Sterilization: Opportunities and Mi- crobial Assessment Strategies in Medical Device Manufacturing [ J ]. IEEE Transaetians on Plasma Science, 2010,38 ( 4 ) : 973 -981. 被引量:1
  • 10Zhao Y,Singh MK,Ogino A,et al. Effects of VUV/UV radiation and oxygen radicals on low - temperature sterilization in surface - wave excited O - 2 plasma [J].Thin Solid Films, 2010,518 ( 13 ) :3590 - 3594. 被引量:1

引证文献2

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部