新型点接触锁定加压接骨板固定骨对骨皮质下血供的影响 被引量:8

Effect of point contact-locking compression plate fixation on blood supply of cortical bone
下载PDF
导出
摘要 目的观察新型点接触锁定接骨板(PC-LCP)和动力加压接骨板(DCP)固定骨后骨皮质微循环形态学及血流量的变化。方法采用成年山羊15只,在左右侧完整胫骨中段分别用PC-LCP和DCP固定。于固定术后1天、2、4、8、12周行非放射性彩色微球测量血流量,术后1天、2、4、8周行活体双硫蓝染色。观察接骨板下与对侧骨血流量及固定段骨接骨板下骨皮质、断端染色变化。结果PC-LCP实验组接骨板下及螺钉之间于术后1天出现骨缺血区,4周时恢复,DCP固定组术后1天、2、4周板下皮质骨持续存在缺血现象,到第8周才恢复;PC-LCP实验组接骨板下血流量均高于DCP组板下血流量。结论PC-LCP对骨皮质骨微循环有明显的保护作用,有利于骨折愈合。 Objective To study the influence of the new design plate PC-LCP ( point contact locking compression plate ) and DCP( dynamic compression plate) on cortical bone blood supply. Methods Fifteen adult goats were fixed on middle shaft of both tibiae with PC-LCP and DCP. Disulphine blue staining was used at 1 st day ,2nd, 4th,8th weeks after surgery and non-radioactive colored microspheres were used to respectively detect blood supply at 1st day ,2nd ,4th ,8th, 12th weeks after surgery. Bone samples were collected aiming to observe the blood supply of the cortical bone. Results The region of the blood perfusion deficiency appeared at 1 st day after PC-LCP fixation,recovered at 4th week. DCP application resulted in a continuous perfusion deficiency under the plate at 1st day ,2nd ,4th weeks and disappeared at 8th weeks after operation; the blood supply of bone cortex was more under the plate PC-LCP than that under the plate DCP all the time. Conclusion The PC-LCP plate can preserve the blood supply of cortical bone beneath the steel plate and improve the fracture healing.
出处 《创伤外科杂志》 2009年第6期533-536,共4页 Journal of Traumatic Surgery
基金 重庆市科技攻关重大项目(CSTC 2006AA5014-1)
关键词 骨折 接骨板 内固定 微循环 血流量 fracture bone plate internal fixation microcirculation blood flow
  • 相关文献

参考文献10

  • 1Palmer RH. BioLogical ostesynthesis [ J ]. Vet Clin North Am Small Anim Pract, 1999,29(5 ) : 1171 - 1185. 被引量:1
  • 2Kregor PJ, Senft D, Parvin D, et al. Cortical bone perfusion in plated fractured sheep tibiae[ J]. J Orthop Res,1995,13 (6) :715 -724. 被引量:1
  • 3邢叔星,王爱民,赵玉峰,刘东北.两种有限接触接骨板固定不同类型骨表面特征评估[J].创伤外科杂志,2007,9(1):49-52. 被引量:3
  • 4Kowallik P,Schutz R,Guth B,et al. Measurements of regional myocardial blood flow with multiple colored microspheres [ J ]. Circulation, 1991,83 ( 3 ) :974 - 982. 被引量:1
  • 5Hale S, Alker K, Klone R. Evaluation of nonradioactive colored microspheres for the measurement of regional myocardial blood flow in dog[J]. Circulation, 1988,78 (2) :428 - 434. 被引量:1
  • 6Hakkinen JP, Miller MW, Smith AH, et al. Measurement of organ blood flow with colored microspheres in the rat[J]. Cardiovasc Res, 1995,29 ( 1 ) :74 - 79. 被引量:1
  • 7John R, Field A, Geoffrey S, et al. Bone blood flow response to surgical trauma [J]. Injury,2002,33 ( 8 ) : 447 - 451. 被引量:1
  • 8Grundnes O, Reikeras O. Blood flow and mechanical properties of healing bone [J]. Acta Orthop Scand, 1992,63 (5) :248. 被引量:1
  • 9Tepic S, Remiger AR, Morikawa K, et al. Strength recovery in fractured sheep tibia treated with a plate or an internal fixator : an experimental study with a two year follow up[ J ]. J Orthop Trauma,1997,11 (1) :14 -23. 被引量:1
  • 10Gunst MA, Uhthoff HK. Interference with bone blood supply through plating of intact bone. Current Concepts of Internal Fixation of fractures [ M ]. Berlin, Springer, 1980. 268 - 276. 被引量:1

二级参考文献8

  • 1Gautier E,Rahn BA,Perren SM.Vascular remodeling[J].Injury,1995,26 (S2):11-19. 被引量:1
  • 2Perren SM,Cordey J,Rahn BA,et al.Early temporary porosis of bone induced by internal fixation implants-a reaction to mecrosis,not to stress protection implants[J].Clin Orthop,1988,(232):139-151. 被引量:1
  • 3Gunst MA,Rahn BA,Ruedi T,et al.Bone blood supply after change of implant[J].Helv Chir Acta,1985,52 (1):177-180. 被引量:1
  • 4Gerber C,Mast JW,Ganz R.Biological internal fixation of fractures[J].Arch Orthop Trauma Surg,1990,109 (6):295-303. 被引量:1
  • 5Palmer RH.Biological osteosynthesis[J].Vet Clin North Am Small Anim Pract,1999,29(5):1171 -1185. 被引量:1
  • 6Field JR,Hearn TC,Caldwell CB.Bone plate fixation:an evaluation of interface contact area and force of the Dynamic Compression Plate (DCP) and the Limited contact-Dynamic Compression Plate (LC-DCP) applied to cadaveric bone[J].J Orthop Trauma,1997,11 (5):368-373. 被引量:1
  • 7John R,Fielda J,Rohan Edmonds-Wilsonb,et al.An evaluation of interface contact profiles in two low contact bone plates[J].Injured,2004,35 (6):551-556. 被引量:1
  • 8赵玉峰,李起鸿,顾祖超,许建中,杨柳.新型点状接触动力加压接骨板的研制(生物力学部分)[J].医用生物力学,2002,17(1):58-62. 被引量:11

共引文献2

同被引文献82

引证文献8

二级引证文献110

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部