摘要 O2是工业过程中广泛应用的重要气体,在工业生产环境下实现O2浓度的快速在线检测对提高燃烧效率和节能减排具有重要的意义。可调谐半导体激光吸收光谱谐波探测技术是一种具有高灵敏、高选择性、快速响应等特点的气体检测新技术,该技术利用了半导体激光器的可调谐和窄线宽特性,通过精心选择待测气体的某条吸收线可排除其他气体的干扰,实现待测气体浓度的高灵敏快速在线检测。文章以可调谐分布反馈(Distributed feedback,DFB)半导体激光器作为光源,通过波长调制方法对760nm附近氧气某一吸收线的二次谐波信号测量,从而实现了对氧气浓度的快速在线检测。系统指标达到:检测范围0.01%~20%;检测精度0.1%;长期稳定性1%。 Oxygen is a widely used important gas in the industrial process. It is very meaningful to on-line monitor the oxygen concentration for the enhancement of combustion efficiency and reduction in environmental pollution. Tunable diode laser absorption spectroscopy (TDLAS) is a highly sensitive, highly selective and fast time response trace gas detection technique. With the features of tunability and narrow linewidth of distributed feedback (DFB) diode laser and by precisely tuning the laser output wavelength to a single isolated absorption line of the gas, TDLAS technique can be utilized to accurately implement gas concentration measurement with very high sensitivity. In the present paper, the authors used a DFB laser was used as the light source, and by employing wavelength modulation method and measuring the second harmonic signal of one absorption line near 760 nm of oxygen molecule, the authors built a system for online monitoring of oxygen concentration. The characteristics of the system are as follows: the scope of detection is 0.01%-20% ; detection accuracy is 0.1 %, long term stability is 1 %.
出处 《光谱学与光谱分析》 SCIE EI CAS CSCD 北大核心 2009年第10期2593-2596,共4页 Spectroscopy and Spectral Analysis
基金 国家"863"计划项目(2007AA06Z420)资助
关键词 可调谐二极管激光吸收光谱(TDLAS) 工业过程控制 O2浓度在线监测 TDLAS Industrial process control O2 concentration online monitoring
  • 相关文献

参考文献2

二级参考文献13

  • 1Platt U and Pemer D 1979 Geophys. Res .84 6329. 被引量:1
  • 2Stutz J and Platt U 1996 Applied Optics 6041. 被引量:1
  • 3Zhou B, Liu W Q and Qi F et al 2001 Acta Phys. Sin .50 1818 (in Chinese). 被引量:1
  • 4Zhou B, Liu W Qand Qi F et al 2001 Research of Environmenz Science 1423(in Chinese). 被引量:1
  • 5Fang K T, Quan H and Chen Q Y 1988 Applied Regression Analysis(Beijing:Science Press)p205(in Chinese) 被引量:1
  • 6Xu S L 1996 C program sas for frequently used Algorithm 2nd Edition ( Beijing: Tsinghua university press) p236( in Chinese ). 被引量:1
  • 7Wienhold F G,Fischer H,Hoor P,et al.TRISTAR-a tracer in situ TDLAS for atmospheric research[J].Applied Physics B,1998,67:411-417. 被引量:1
  • 8Nadezhdinskii A,Berezin A,Chernin S,et al.High sensitivity methane analyzer based on tuned near infrared diode laser[J].Spectrochimica Acta Part A,1999,55:2083-2089. 被引量:1
  • 9Anatoliy A,Kosterev,Alexander L,et al.Cavity ringdown spectroscopic detection of nitricoxide with a continuous-wave quantum-cascade laser[J].Applied optics,2001,40:5522-5529. 被引量:1
  • 10Anatoliy A,Kosterev,Frank K,et al.Thermoelectrically cooled quantum-cascade-laser-based sensor for the continuous monitoring of ambient atmospheric carbon monoxide[J].Applied optics,2002,41:1169-1173. 被引量:1