期刊文献+

忠武管道气液联动阀故障分析及改进措施 被引量:4

Fault Analysis of Gas-liquid Valve and Improvement in Zhongxian-Wuhan Gas Transmission Pipeline
下载PDF
导出
摘要 忠武输气管道投产以来多次发生气液联动阀误关断事故。分析结果表明,设备选型不当导致供电系统不可靠以及设备本身缺陷是阀误关断的主要原因。提出了改进供电系统、加强绝缘保护、完善控制软件等整改措施。 Faulty shut-off operation of gas-liquid valve had occurred time after time in Zhongxian-Wuhan Gas Transmission Pipeline after its commissioning.Analysis results display that one of the mam causes of the faulty shut-off operation in the gas-liquid valve is the misselection of equipment.which results in low reliability of power supply system,and the other is the defects existed in equipment itself.Technical modification measures on improving power supply system,strengthen insulating protection and perfecting control software are proposed.
出处 《油气储运》 CAS 北大核心 2009年第9期33-36,共4页 Oil & Gas Storage and Transportation
关键词 气液联动阀 误关断 技术改造 故障 gas-liquid valve.faulty shut-off operation.technique.improvement
  • 相关文献

同被引文献37

引证文献4

二级引证文献21

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部