摘要
文章对中国石油化工股份有限公司武汉分公司催化裂化装置2004年~2008年运行周期的设备腐蚀和检验情况进行了详细地描述,分析了造成设备腐蚀的主要原因,并针对下一周期设备防护问题提出了具体防腐蚀措施和建议。
This article describes, in detail, the corrosion and its analysis for the FCC unit over the period of year 2004 -2008. The main causes of corrosion were analyzed. The methods and suggestions for corrosion prevention for the next period are described.
出处
《石油化工腐蚀与防护》
CAS
2009年第B05期125-128,142,共5页
Corrosion & Protection In Petrochemical Industry
关键词
催化裂化
高温硫腐蚀
低温腐蚀
腐蚀与防护
FCC, high - temperature sulfur corrosion, low - temperature corrosion, corrosion and prevention