期刊文献+

短弧对汽车继电器触头动熔焊的影响 被引量:14

Influence of Short Arc on Contacts Dynamic Welding of Automotive Relay
下载PDF
导出
摘要 触点熔焊是汽车继电器最为严重的故障,它可能导致汽车事故。介绍了造成继电器触点动熔焊的电弧类型,指出闭合短电弧是动熔焊的直接原因。分析了短电弧的产生机理和基本特性,指出了触点弹跳时间决定闭合短电弧的时间。 Contact welding of automotive relay is the worst failure and may result in serious car accident. The arc types that make the relay contact dynamic welding occur were introduced. It was pointed out that the closing short arc is direct reason of dynamic welding. The short arc ignition and its characteristics were analysed. It was also pointed out that contact bounce duration decided the closing short arc duration.
出处 《低压电器》 北大核心 2007年第1期10-13,21,共5页 Low Voltage Apparatus
基金 国家自然科学基金资助项目(50477044)
关键词 电弧 电磁继电器 动熔焊 arc electromagnetic relay dynamic welding
  • 相关文献

参考文献9

  • 1WERNER W R. Contact Welding Influenced by Anode Arc And Cathode Arc [ C ]//Respectively, Proceedings of the 50th IEEE Holm Conference on Electrical Contacts and the 22rid International Conference on Electrical Contacts, Sept 2004:378-381. 被引量:1
  • 2CHEN Zhuanke, WITTER G. Electrical Contacts for Automotive Applications : A Review[ J]. IEICE Transactions on Electronics, 2004, E87-C (8) : 1248-1254. 被引量:1
  • 3SCHOEPF T J, ROWLANDS R, DREW G. Contact Welding at Break of Motor Inrush Current [ C]//Proceedings of the 50th IEEE Holm Conference on Electrical Contacts and the 22nd International Conference on Electrical Contacts, Sept 2004:362-369. 被引量:1
  • 4NEUHAUS A R, RIEDER W F, HAMMERSCHMIDT M. Influence of Arc Duration and Current on Contact Welding in Low Power Switches [ C ]//Proceedings of the Forty-Eighth IEEE Holm Conference on Electrical Contacts, Oct 2002 : 17-20. 被引量:1
  • 5DOUBLET L, BEN J N, HAUNER F, et al. Make Arc Erosion and Welding Tendency under DC 42 V in Automotive Area[ C ]//Proceedings of the Forty-Ninth IEEE Holm Conference on Electrical Contacts, Sept 2003 : 158-162. 被引量:1
  • 6DIETRICH A. Micro-Arcs at Make and Break Processes[C]//Proceedings of the 50th IEEE Holm Conference on Electrical Contacts and the 22nd International Conference on Electrical Contacts, Sept 2004 : 395- 402. 被引量:1
  • 7TOMOYA I. Growth of Transferred Pip and Electrical Properties of AgCdO Make Only Contacts in Resistive Circuit with DC14V and DC 42 V Power Supply[J]. IEICE Trans on Electron, 2005, E88-C ( 8 ) : 1670- 1674. 被引量:1
  • 8SCHOEPF T J. Counter-Measures for Relay Failures due to Dynamic Welding: a Robust Engineering Design [ C]//Proceedings of the Fifty-First IEEE Holm Conference on Electrical Contacts, Sept 2005:352-359. 被引量:1
  • 9CHEN Zhuanke. The Effect of Silver Composition and Additives on Switching Characteristics of AgSnO2 Type Contacts for the Automotive Inductive Loads [ C ]//Proceedings of the Fifty-First IEEE Holm Conference on Electrical Contacts, Sept 2005:35-41. 被引量:1

同被引文献93

引证文献14

二级引证文献50

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部