高温合金中多元素辉光放电质谱法测定及干扰校正 被引量:2

Determination of multi-elements in superalloy by glow discharge mass spectrometry and interference correction
下载PDF
导出
摘要 通过辉光放电质谱法(GDMS)测定了高温合金中的C,Mg,Al,P,S,Ti,V,Cr,Mn,Fe,Co,Cu,Nb,Mo,W共15种元素。对辉光放电参数如电流、电压、预溅射时间进行了优化;对高温合金中的质谱干扰进行了分析并详细叙述了各分析元素的干扰情况。选择丰度大且不受干扰或干扰少的同位素用于分析,大多数元素测定结果很好。对于仍存在干扰的元素通过数学校正的方法进行质谱干扰校正。建立干扰校正公式,成功地消除了62Ni2+和36Ar12C+对31P+和48Ti+的质谱干扰。在优化的实验条件下,建立工作曲线。直接对2块高温合金标准样品进行测定,分析结果与认定值吻合,大部分元素的相对标准偏差(RSD)小于5%。 Fifteen elements i.e. C, Mg, Al, P, S, Ti, V, Cr, Mn, Fe, Co, Cu, Nb, Mo and W in superalloy were determined by glow discharge mass spectrometry (GDMS). The glow discharge parameters such as current, voltage, and pre-burn time were optimized. The mass interferences in superalloy were analyzed,and the interferences of analysis isotopes were described in detail. After isotopes with high abundance, non-interference or light interference were selected for analysis, most elements could be determined very well, while for the elements which are still interfered a mathematic correction method was used to correct the mass spectral interferences. Correction formulas were established in this experiment, and then the mass spectral interferences of 62^Ni^2+ and 36^Ar^12C^+ to 31^p^+ and 48^Ti^+ have been removed successfully. Under the optimized experiment conditions, the calibration curves were established, and two pieces of superalloy standard samples were directly determined. The analysis results were close with certified values of standard samples, moreover, the relative standard deviations (RSDs) of most elements were less than 5 %.
机构地区 钢铁研究总院
出处 《冶金分析》 EI CAS CSCD 北大核心 2007年第4期11-17,共7页 Metallurgical Analysis
基金 科技部新技术 新方法基金项目(2003-34)
关键词 辉光放电质谱法 高温合金 干扰校正 多元素 测定 glow discharge mass spectrometry superalloy interference correction multi-element determination
  • 相关文献

参考文献16

  • 1Becker J S, Dietze H - J. Inorganic trace analysis by mass spectrometry [J]. Spectrochimica Acta-Part B, 1998,53:1475- 1506. 被引量:1
  • 2Sanderson N E, Hall E, Clark J, et al. Glow discharge mass spectrometry a powerful technique for the elemental analysis of solids[J], Mikrochim. Acta. , 1987, 1:275 - 290. 被引量:1
  • 3Gijbels R, Van Straaten M, Bogaerts A. Mass spectrometric analysis of inorganic solids: GDMS and other methods[J]. Adv. Mass Spectrom., 1995,13:241 - 256. 被引量:1
  • 4Bogaerts A, Gijbels R. New developments and application in GDMS[J]. Fresenius J'. Anal. Chem. 1999,364 : 367 - 375. 被引量:1
  • 5Hoffmann V, Kasik M, Robinson P K,et al. Glow discharge mass spectrometry [ J ]. Anal, Bioanal. Chem., 2005,381:173 - 188. 被引量:1
  • 6Krishna M V B, Shekhar R, Karunasagar D, et al. Multi-element characterization of high purity cadmium using inductively coupled plasma quadrupole mass spectrometry and glow-discharge quadrupole mass spectrometry [J ]. Anal. Chim. Acta., 2000,408-199 - 207. 被引量:1
  • 7Adams F, Vertes A. Inorganic mass spectrometry of soild samples[J]. Fresenius J. Anal. Chem. , 1990,337 : 638 - 647. 被引量:1
  • 8Lim J - W, Mimura K, Isshiki M. Application of glow discharge mass spectrometry for direct trace impurity analysis in Cu films[J], Applied Surface Science, 2004, 227 : 300 - 305. 被引量:1
  • 9Shekhar R, Arunachalam J, Das N, et al. Multielemental characterisation of cobalt by glow discharge quadrupole mass spectrometry [ J ]. Talanta, 2005, 65:1270 - 1278. 被引量:1
  • 10Mykytiuk A P, Semeniuk P, Berman S. Analysis of high purity metals and semiconductor materials by glow discharge mass spectrometry [ J ]. Spectrochim, Acta Rev, 1990,13 : 1 - 10. 被引量:1

二级参考文献26

  • 1Becker J S, Dietze H - J. Inorganic trace analysis by mass spectrometry [ J ]. Spectrochimica Acta: Part B, 1998,53 :1475- 1506. 被引量:1
  • 2Sanderson N E, Hall E, Clark J, et al. Glow discharge mass spectrometry - a powerful technique for the elemental analysis of solids [J]. Mikrochim. Acta, 1987,1:275 -290. 被引量:1
  • 3Gijbels R, Van Straaten M, Bogaerts A. Mass spectrometric analysis of inorganic solids: GDMS and other methods [J]. Adv. Mass Spectrom. , 1995,13:241 - 256. 被引量:1
  • 4Harrison W W, Hang W, Yan X, et al. Temporal oonsiderations with a microsecond plused glow discharge [ J ]. J.Anal. At. Spectrom. , 1997,12:891-896. 被引量:1
  • 5Saprykin A I, Becker J S, Dietze H - J. Characterization and optimization of a radiofrequency glow discharge ion source for a high resolution mass spectrometer [J ]. J. Anal. At. Spectrom., 1995,10: 897 - 901. 被引量:1
  • 6Bogaerts A, Gijbels R. New devdopments and application in GDMS [J]. Fresenius J. Anal. Chem., 1999,364:367- 375. 被引量:1
  • 7Hoffmann V, Kasik M, Robinson P K, et al. Glow discharge mass spectrometry [J]. Anal. Bioanal. Chem., 2005,381 : 173 - 188. 被引量:1
  • 8Krishna M V B,Shekhar R,Karunasagar D,et al.Multielement characterization of high purity cadmium using inductively coupled plasma quadrupole mass spectrometry and glow-discharge quadrupole mass spectrometry[J].Analytica Chimica Acta,2000,408:199-207. 被引量:1
  • 9Adams F,Vertes A.Inorganic mass spectrometry of soild samples[J].Fresenius J.Anal.Chem.,1990,337:638-647. 被引量:1
  • 10Lim J -W,Mimura K,Isshiki M.Application of glow discharge mass spectrometry for direct trace impurity analysis in Cu films[J].Applied Surface Science,2004,227:300-305. 被引量:1

共引文献4

同被引文献52

引证文献2

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部