摘要
在用反平衡法对电站锅炉进行热效率计算的基础上,提出了运行参数偏离目标值所引起的煤耗偏差计算模型,并具体给出了锅炉主要运行参数变化与煤耗变化的关系式。
A calculation model of coal consumption deviation due to operation parameters deviated from the target value was presented on the basis of thermal efficiency computation of thermal power plant boiler with the anti-balance method.The relational expression of its operation parameters and the coal consumption was specifically given.
出处
《节能》
2006年第11期27-28,共2页
Energy Conservation
关键词
电站锅炉
运行参数
煤耗偏差
目标值
power plant boiler
operation parameters
deviation of coal consumption
target value