摘要
介绍了云冈热电锅炉结渣及其治理情况,通过合理的燃烧器改造和深入的试验研究及调整工作,彻底改变了锅炉结渣状况,提高了机组安全稳定和经济环保运行性能,为类似问题的解决提供了良好的借鉴。
The boiler slagging and solution options chosen in Yungang Cogeneration Power Plant are presented. After rational renovation and adjustment of burner based on further research ,the boiler slagging problem is completely resolved. The unit's performance is enhanced in terms of safe ,stable ,economical and environmental friendly operation. This could be used for reference for similar problems.
出处
《华北电力技术》
CAS
2006年第4期23-26,共4页
North China Electric Power
关键词
结渣
燃烧器改造
试验
优化调整
slagging
renovation of burner
test
optimal adjustment