摘要
在多区域空调系统中,由于多区效应的存在,使得在满足各区域空气品质要求与降低能耗之间的权衡成了一个很大的难题。本文分析了3种确定系统新风比的方法,并采用仿真方法,从能量、各区域空气品质角度对它们的优劣进行了对比。
For central air condition system which one air handling unit (AHU) serves multiple spaces, there is a problem that the uniqueness of outdoor air ratio can not satisfy various demands of multiple spaces. It is a key issue to reduce the energy consumption while the indour air quality (IAQ) of each space reaches the rules of ASHRAE Standard. Three control strategies are analyzed via simulation in this paper, and they are demonstrated and compared in performances of energy consumption and IAQ.
出处
《流体机械》
CSCD
北大核心
2006年第1期32-34,5,共4页
Fluid Machinery
关键词
变风量
空调系统
多区
新风控制
AHU
VAV
air-conditioning system
multi-zone
outdoor air control
air handling unit