摘要
以天津市某体育馆为研究对象,针对体育馆的构造特点、体育馆的使用情况,提出4种常见的送风形式,利用CFD软件对体育馆进行物理建模;通过模拟结果分析和比较针对各种不同的气流组织方式下体育馆内CO2浓度在空间上的分布情况,最终提出不同气流组织方式对体育馆新风控制的影响,并提出解决措施。
Taking a stadium in tianjin as the research object,based on the structure feature of the gym,on the basis of the usage in the gym, four kinds of common forms of air supply are put forward,using CFD software to physical modeling of the gym,through the simulation results analysis and comparison for different air distribution modes gymnasium CO2 concentration on the space distribution,finally put forward different air distribution methods on stadium fresh air control effect, and puts forward some solving measures.
出处
《节能》
2013年第9期42-45,3,共4页
Energy Conservation
关键词
气流组织
新风
控制
影响
体育馆
airflow organization
fresh air
control
stadium