针对太原第一热电厂2台300MW火力发电机组的8台钢球磨系统稳定性、煤粉的均匀性较差,甚至发生断煤、超压、超温或堵煤等现象进行合理分析,运用自寻优-模糊控制的原理对该钢球磨系统进行优化处理,并结合WDPF-II控制系统详细设计了可行性优化实施方案。
This paper expounds an optimizing control system (WDPF-Ⅱ) for the mill. The fuzzy control method can deal with the phenomenon such as going beyond temperature or pressure, and the phenomenon such as being lack of coal or blocking up coal.