摘要
结合太原第一热电厂13号、14号机组凝汽器胶球清洗系统的运行情况,总结出影响胶球系统收球率的因素,阐述了相关胶球系统的一些改进措施,并提出一些建议供同类型机组参考。
Based on the condenser operation condition of No. 13 and No. 14 generator in Taiyuan No. 1 thermal power plant, change causes of the rate of gluey ball recovery is summerized. The effective measures to improve gluey system is also put forward. Some suggestions are proposed for the refenence of the same type.
出处
《山西电力》
2007年第4期31-33,共3页
Shanxi Electric Power
关键词
凝汽器
胶球清洗
收球率
建议
condenser
gluey ball cleaning
the rate of ball recovery
suggestion