期刊文献+

CNTs化学修饰的γ剂量效应 被引量:3

Effects of γ-ray irradiation dose on modification of multi-wall carbon nanotubes
下载PDF
导出
摘要 Multi-wall carbon nanotubes(MWNTs) were irradiated to different doses by Co γ-rays, and were subjected 60 to chemical modification with decylamin. Elemental and TGA analyses of the modified MWNTs indicated that concentration of the functional groups bound to MWNTs increased monotonously with increasing doses, due to the defects created on the MWNTs by the γ-rays. In contrast with the results reported in Ref.1, no saturation of defect concentration was found at 170 kGy in this work. Multi-wall carbon nanotubes(MWNTs) were irradiated to different doses by Co γ-rays, and were subjected 60 to chemical modification with decylamin. Elemental and TGA analyses of the modified MWNTs indicated that concentration of the functional groups bound to MWNTs increased monotonously with increasing doses, due to the defects created on the MWNTs by the γ-rays. In contrast with the results reported in Ref.1, no saturation of defect concentration was found at 170 kGy in this work.
出处 《辐射研究与辐射工艺学报》 CAS CSCD 北大核心 2005年第2期112-112,共1页 Journal of Radiation Research and Radiation Processing
基金 国家自然科学基金(10475109)资助
关键词 多壁碳纳米管 Γ射线辐照 化学修饰 剂量效应 MWNTs, γ-ray irradiation, Chemical modification, Defect saturation
  • 相关文献

参考文献1

  • 1Skakalova V, Dettlaff-weglikowska U, Roth S. Diamond Relat Mater, 2004, 13(2): 296-298. 被引量:1

同被引文献31

  • 1郭金学,李宇国,吴胜伟,李文新.多壁碳纳米管γ辐照后的化学修饰[J].辐射研究与辐射工艺学报,2005,23(3):155-158. 被引量:5
  • 2郭金学,李文新.γ辐照后MWNTs的水溶性修饰[J].辐射研究与辐射工艺学报,2006,24(4):193-196. 被引量:3
  • 3Eddy Segura PINO,Luci Diva Brocardo MACHADO,Claudia GIOVEDI.Improvement of carbon fiber surface properties using electron beam irradiation[J].Nuclear Science and Techniques,2007,18(1):39-41. 被引量:5
  • 4Ruygrok PN.The Coherex Flat Stent:an advance in patent foramen ovale closure[J].Expert Rev Med Devices,2010,7:193-199. 被引量:1
  • 5Radeleff B,Grenacher L,Christoph P.Comparison of a microporous thermoplastic polyurethane-covered stent with a self-expanding bare nitinol stent in a porcine iliac artery model[J].J Vasc Interv Radiol,2009,20:927-935. 被引量:1
  • 6Schuman E,Babu J.Sirolimus-loaded polyurethane graft for hemodialysis access in sheep[J].Vascular,2008,16:269-274. 被引量:1
  • 7Anderson JM,Hiltner A,Wiggins MJ,et al.Recent advances in biomedical polyurethane biostability and biodegradation[J].Polymer International,1998,46:163. 被引量:1
  • 8Xu Y,Mahmood M,Fejleh A,et al.Carbon-covered magnetic nanomaterials and their application for the thermolysis of cancer cells[J].Int J Nanomedicine,2010,7:167-176. 被引量:1
  • 9Szelest-Lewandowska A,Masiulanis B,Szymonowicz M,et al.Modified polycarbonate urethane:synthesis,properties and biological investigation in vitro[J].J Biomed Mater Res A,2007,82:509-520. 被引量:1
  • 10Misra SK,Ansari TI,Valappil SP,et al.Poly(3-hydroxybutyrate) multifunctional composite scaffolds for tissue engineering applications[J].Biomaterials,2010,31:2806-2815. 被引量:1

引证文献3

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...