期刊文献+

无创式微型动态血压监护仪的设计(英文)

A new portable non-invasive sphygmomanometer for dynamic blood pressure measurement
下载PDF
导出
摘要 目的:研制一种无创式微型动态血压监护仪。方法:以一片80c196单片机和一个高分辨率液晶显示器(LCD)为基础,采用振动法原理和数据处理技术实现血压参数的实时检测和显示。结果:系统可动态实时显示所采集的血压波形和检测参数,并可存储显示24h内的血压数据信号,通过RS232接口可完成与计算机之间的数据通讯。结论:该仪器小型轻便,使用灵活,有较强的抗干扰能力,具有很大的应用价值。 AIM:To develop a non-invasive portable monitor for accurate dynamic blood pre ssure(BP) measurement. METHODS:With a piece of 80c196 singlechip and a high-differentiation LCD,a ne w portable monitor could carry out real-time examination and display of BP para meters on the basis of oscillometric method theory and data processing technique . RESULTS:System could dynamically show real-time BP wave shape and parameters, which then stored in computer for 24 hours for inter-computer communication thr ough RS232 interface. CONCLUSION:This kind of sphygmomanometer was of great applicable value because of mini-type and portability,as well as agile usage and anti-interference cap ability.
出处 《中国临床康复》 CSCD 2004年第15期2976-2977,共2页 Chinese Journal of Clinical Rehabilitation
基金 国家"八六三"计划资助项目(863-306-ZD-0502)~~
  • 相关文献

参考文献2

二级参考文献10

  • 1Schradcr J, Schoel G, Buhr-Schinner H, ct al. Companeon of the antihypertcnsive efficiency of mtrcndipinc, mctoprolol, mepindolol and enalapnl using ambulatory 24-hour blood pressure monitoring. Am J Cardolol 1990; 66 (12):967- 72. 被引量:1
  • 2Sokolow M, Werdegax D, Kain-HK,Hinman AT. Relationship between level of blood pressure measured casually and hy portable recorders and severity of complications in essential hypertension. Circulation 1966; 34(2): 279 -98. 被引量:1
  • 3Novo S,Abrignani MG,Novo G,et al.Effects of drug therapy on cardiac arrhythmias and ischemia in hypertensives with LVH. Am J Hypertens 2001; 14(7 Pt 1 ): 637 -43. 被引量:1
  • 4Picano E, Palinkas A, Amyot R Diagnoeis of myocardial ischemia in hypertensive pehents. J Hypertens 2001 ; 19(7): 1177 -83. 被引量:1
  • 5Ma WY. Zhu QY. Shen Y. et al. The value of ambulatory blood pressuremonitoring in redicting targe organ damage caused by hypertension. Linchuang Xinxueguanbing Zazhi( J Clin Cardiol) 2000; 16:399 -401. 被引量:1
  • 6Wang ZS, Liu CW, Ma S, et al. ambulatory electrocardiogram and monitoring electrocardiogram.In: Yang JG. Modern electrocardiogram. Beijing: Science Publishing Company 1997:956 - 79. 被引量:1
  • 7Gong LS, Zhang WZ, Wang XY, et al. Clinical character and diagnisis of the essential hypvrtcnsion. In: Chcn MZ. Heart disease. Beijing: Publishing Company of Beijing Medical University 1999:803 - 15. 被引量:1
  • 8Zhu PX. The relationship between of ambulatory blood pressure load and bcarl diastolic function. Xiandai Kungfu(Mod Rehabil) 2001; 5(2): 105. 被引量:1
  • 9Liu ZQ. Clinical evaluation of danger factor of target organ damage and artery sclerosis in pahents with the essential hypertension. In: Liu ZQ, Mou JJ. Diaguosis iatreusiology of hypertensive disease. Beiting: Publishing Company of Beijing Medical University and Beijing Unite Medical University 1998:41-53. 被引量:1
  • 10花放,刘文瑞,丁晓慧,方秀斌.降钙素基因相关肽神经保护作用的机制研究[J].现代康复,2001,5(2):54-55. 被引量:18

共引文献27

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部