期刊文献+

自然通风逆流式冷却塔配水型式比较 被引量:3

Comparison of Two Types of Water Distribution Mode for Natural Ventilation Reverse Flow Cooling Towers
原文传递
导出
摘要 结合工程实例 ,通过对自然通风逆流式冷却塔套筒式竖井配水和虹吸式竖井配水 2种配水型式 ,在配水均匀性、水力计算的合理性、系统布置和运行操作 4个方面的技术比较及 2种配水型式的经济比较表明 ,虹吸式竖井配水是一种技术先进。 In combination with the engineering practice the technical and economical comparison on two kinds of water distribution (sleeve type shaft and suction type shaft)with four aspects including uniformity of water distribution,rationalization of hydraulic calculation,system arrangement and operation for natural ventiloation reverse flow cooling towers indicate that the water distribution by means of suction type shaft is a type of water distribution with advanced technology,high effecient economy.It is suitable for wide popularization.
作者 曾建柱
出处 《电力建设》 北大核心 2002年第4期29-30,40,共3页 Electric Power Construction
关键词 自然通风逆流式冷却塔 配水型式 套筒式竖井配水 虹吸式竖井配水 natural ventilation reverse flow cooling tower water distribution type sleeve type shaft distribution suction type shaft distribution