摘要
分析了汽动给水泵的故障原因,采取措施予以消除,并且对给水泵的各种工况的运行方式进行分析,从而提高了给水泵运行的可靠性和经济性。
The reason of trouble in the steam-driven feed water pump has been analyzed in the paper and the eounter measure has been adopted. Based on the analysis of the operation mode under all kinds of working conditions, the feasibility and economy of the pump operation have been increased.
出处
《电站辅机》
2005年第2期27-29,39,共4页
Power Station Auxiliary Equipment
关键词
给水泵
运行方式
故障跳闸
feed water pump
Operation mode
emergency shutoff