Radio frequency/microwave-directed energy sources using wide bandgap SiC photoconductive semiconductors have attracted much attention due to their unique advantages of high-power output and multi-parameter adjustable ...Radio frequency/microwave-directed energy sources using wide bandgap SiC photoconductive semiconductors have attracted much attention due to their unique advantages of high-power output and multi-parameter adjustable ability.Over the past several years,benefitting from the sustainable innovations in laser technology and the significant progress in materials technology,megawatt-class output power electrical pulses with a flexible frequency in the P and L microwave wavebands have been achieved by photoconductive semiconductor devices.Here,we mainly summarize and review the recent progress of the high-power photonic microwave generation based on the SiC photoconductive semiconductor devices in the linear modulation mode,including the mechanism,system architecture,critical technology,and experimental demonstration of the proposed high-power photonic microwave sources.The outlooks and challenges for the future of multi-channel power synthesis development of higher power photonic microwave using wide bandgap photoconductors are also discussed.展开更多
This study proposes a method for measuring the operational current of high temperature superconducting(HTS)non‐insulation(NI)closed‐loop coils,which operate in the steady persistent‐current‐mode(PCM).HTS NI closed...This study proposes a method for measuring the operational current of high temperature superconducting(HTS)non‐insulation(NI)closed‐loop coils,which operate in the steady persistent‐current‐mode(PCM).HTS NI closed‐loop coils are promising for many easily‐quenching direct‐current(DC)applications,where their performance is determined by magnetomotive forces,total number of turns,and dimensions.As the primary interface parameter in an application system,the operational current must be accurately and rapidly measured.Generally,this is achieved by dividing the measured magnetic field by the coil constant.However,even if the influence of the screening current induced field(SCIF)is not considered,existing methods for the coil constant may be disturbed by the performance and location of Hall sensors,or experience a long measuring period.Therefore,a relatively accurate and fast method is proposed in this study,which is based on adjusting the output current of the adjustable power supply and monitoring the coil voltage as an indicator.The proposed method was validated through experiments and simulations using an equivalent circuit model coupled with a finite element method(FEM)model,and its current accuracy can be equivalent to the resolution of the employed power supply.It was demonstrated that this method reduced the requirements for Hall sensor’s performance and location,and has a more reliable accuracy in contrast to the simulation method.Compared to the experimentally conventional method,the proposed method presents a significantly faster speed.The impact of the SCIF was considered and proven to be negligible for the tested pancake coils.Even for coils whose coil constant vibrates owing to the SCIF,this method can be adapted to directly measure various operational currents.Furthermore,it was demonstrated that the measurement error can be influenced by the current discrepancy among turns when the coil is not in the steady PCM,and a procedure for reducing this error was proposed.展开更多
Single event latch-up (SEL) is a significant issue for electronics design in space application, which would cause large currents in electronic devices, and may lead to burning out of devices. A new monitoring circuit ...Single event latch-up (SEL) is a significant issue for electronics design in space application, which would cause large currents in electronic devices, and may lead to burning out of devices. A new monitoring circuit based on current-comparing method is designed to protect the electronics away from SEL’s damage in radiation environment. The response time of protection circuit has been analyzed. The signal simulation results indicated that the operating time of the SEL protection circuit is dependent on the action time of current comparator and system application recovery time. The function of the monitoring circuit protection device away from SEL’s damage has validated through experiment at last.展开更多
基金supported in part by the National Natural Science Foundation of China(Nos.62071477 and 62101577)the Natural Science Foundation of Hunan Province(No.2021JJ40660)。
文摘Radio frequency/microwave-directed energy sources using wide bandgap SiC photoconductive semiconductors have attracted much attention due to their unique advantages of high-power output and multi-parameter adjustable ability.Over the past several years,benefitting from the sustainable innovations in laser technology and the significant progress in materials technology,megawatt-class output power electrical pulses with a flexible frequency in the P and L microwave wavebands have been achieved by photoconductive semiconductor devices.Here,we mainly summarize and review the recent progress of the high-power photonic microwave generation based on the SiC photoconductive semiconductor devices in the linear modulation mode,including the mechanism,system architecture,critical technology,and experimental demonstration of the proposed high-power photonic microwave sources.The outlooks and challenges for the future of multi-channel power synthesis development of higher power photonic microwave using wide bandgap photoconductors are also discussed.
基金supported by National Natural Science Foundation of China(NSFC)under project 51977130.
文摘This study proposes a method for measuring the operational current of high temperature superconducting(HTS)non‐insulation(NI)closed‐loop coils,which operate in the steady persistent‐current‐mode(PCM).HTS NI closed‐loop coils are promising for many easily‐quenching direct‐current(DC)applications,where their performance is determined by magnetomotive forces,total number of turns,and dimensions.As the primary interface parameter in an application system,the operational current must be accurately and rapidly measured.Generally,this is achieved by dividing the measured magnetic field by the coil constant.However,even if the influence of the screening current induced field(SCIF)is not considered,existing methods for the coil constant may be disturbed by the performance and location of Hall sensors,or experience a long measuring period.Therefore,a relatively accurate and fast method is proposed in this study,which is based on adjusting the output current of the adjustable power supply and monitoring the coil voltage as an indicator.The proposed method was validated through experiments and simulations using an equivalent circuit model coupled with a finite element method(FEM)model,and its current accuracy can be equivalent to the resolution of the employed power supply.It was demonstrated that this method reduced the requirements for Hall sensor’s performance and location,and has a more reliable accuracy in contrast to the simulation method.Compared to the experimentally conventional method,the proposed method presents a significantly faster speed.The impact of the SCIF was considered and proven to be negligible for the tested pancake coils.Even for coils whose coil constant vibrates owing to the SCIF,this method can be adapted to directly measure various operational currents.Furthermore,it was demonstrated that the measurement error can be influenced by the current discrepancy among turns when the coil is not in the steady PCM,and a procedure for reducing this error was proposed.
文摘Single event latch-up (SEL) is a significant issue for electronics design in space application, which would cause large currents in electronic devices, and may lead to burning out of devices. A new monitoring circuit based on current-comparing method is designed to protect the electronics away from SEL’s damage in radiation environment. The response time of protection circuit has been analyzed. The signal simulation results indicated that the operating time of the SEL protection circuit is dependent on the action time of current comparator and system application recovery time. The function of the monitoring circuit protection device away from SEL’s damage has validated through experiment at last.