BACKGROUND Knee and hip osteoarthritis affects millions of people around the world and is expected to rise even more in frequency as the population ages.Joint arthroplasty is the surgical management of choice in these...BACKGROUND Knee and hip osteoarthritis affects millions of people around the world and is expected to rise even more in frequency as the population ages.Joint arthroplasty is the surgical management of choice in these articulations.Heterotopic ossi-fication and radiolucent lines formation are two frequent problems faced in hip and knee replacements respectively.Some studies show that the usage of pulsed lavage may prevent their formation.AIM To compare pulsed lavage to standard lavage in joint arthroplasty.METHODS PubMed,Cochrane,and Google Scholar(page 1-20)were searched till December 2023.Only comparative studies were included.The clinical outcomes evaluated were the heterotopic ossification formation in hip replacements,radiolucent lines formation,and functional knee scores in knee replacements.RESULTS Four studies met the inclusion criteria and were included in this meta-analysis.Pulsed lavage was shown to reduce the formation of radiolucent lines(P=0.001).However,no difference was seen in the remaining outcomes CONCLUSION Pulsed lavage reduced the formation of radiolucent lines in knee replacements.No difference was seen in the remaining outcomes.Furthermore,the clinical significance of these radiolucent lines is poorly understood.Better conducted randomized controlled studies and cost-effectivity studies are needed to reinforce these findings.展开更多
Friction is a genuine issue in the use of many medical devices involving rubbery materials such as plungers in medical syringes. This paper presents a new direction for the reduction of friction in medical syringes ba...Friction is a genuine issue in the use of many medical devices involving rubbery materials such as plungers in medical syringes. This paper presents a new direction for the reduction of friction in medical syringes based on surface texturing of the rubber plunger. The specimens were prepared by casting poly(vinylsiloxane)(PVS) rubber into a pre-fabricated negative template obtained by 3D printing. Friction tests were performed on a home-made test-rig. It was clearly shown that friction resistance can be considerably manipulated when using textured plungers.展开更多
文摘BACKGROUND Knee and hip osteoarthritis affects millions of people around the world and is expected to rise even more in frequency as the population ages.Joint arthroplasty is the surgical management of choice in these articulations.Heterotopic ossi-fication and radiolucent lines formation are two frequent problems faced in hip and knee replacements respectively.Some studies show that the usage of pulsed lavage may prevent their formation.AIM To compare pulsed lavage to standard lavage in joint arthroplasty.METHODS PubMed,Cochrane,and Google Scholar(page 1-20)were searched till December 2023.Only comparative studies were included.The clinical outcomes evaluated were the heterotopic ossification formation in hip replacements,radiolucent lines formation,and functional knee scores in knee replacements.RESULTS Four studies met the inclusion criteria and were included in this meta-analysis.Pulsed lavage was shown to reduce the formation of radiolucent lines(P=0.001).However,no difference was seen in the remaining outcomes CONCLUSION Pulsed lavage reduced the formation of radiolucent lines in knee replacements.No difference was seen in the remaining outcomes.Furthermore,the clinical significance of these radiolucent lines is poorly understood.Better conducted randomized controlled studies and cost-effectivity studies are needed to reinforce these findings.
基金funded by Maof Fellowships, the Council for Higher Education of Israel (Dr. H. Kasem)the MIA program the Ministry of Science, Technology & Space (Prof. A. Domb)
文摘Friction is a genuine issue in the use of many medical devices involving rubbery materials such as plungers in medical syringes. This paper presents a new direction for the reduction of friction in medical syringes based on surface texturing of the rubber plunger. The specimens were prepared by casting poly(vinylsiloxane)(PVS) rubber into a pre-fabricated negative template obtained by 3D printing. Friction tests were performed on a home-made test-rig. It was clearly shown that friction resistance can be considerably manipulated when using textured plungers.