In building Shanghai Synchrotron Radiation Facility(SSRF), in order to reduce or eliminate the unnecessary sources of beam motion, the precise and stable beam position measurement system in the feedback system was req...In building Shanghai Synchrotron Radiation Facility(SSRF), in order to reduce or eliminate the unnecessary sources of beam motion, the precise and stable beam position measurement system in the feedback system was required. In this study, we focused on theoretical analysis of the electrode of beam position monitor(BPM).Simulations, including analytic derivations of the propagation impedance and the distribution inductance, were performed. The BPM was designed based on the results and the acceptance measurements of the impedance and the inductance by using the time domain reflection(TDR) with a network analyzer. It has been proved in years of operations that the BPM system meets the requirement of the resolution of sub-micron.展开更多
基金Supported by the National Natural Science Foundation of China(No.11375255)
文摘In building Shanghai Synchrotron Radiation Facility(SSRF), in order to reduce or eliminate the unnecessary sources of beam motion, the precise and stable beam position measurement system in the feedback system was required. In this study, we focused on theoretical analysis of the electrode of beam position monitor(BPM).Simulations, including analytic derivations of the propagation impedance and the distribution inductance, were performed. The BPM was designed based on the results and the acceptance measurements of the impedance and the inductance by using the time domain reflection(TDR) with a network analyzer. It has been proved in years of operations that the BPM system meets the requirement of the resolution of sub-micron.