A novel modified electrode was prepared by electrochemicaly cycling scanning the glass carbon electrode covered with a macroporous alumina membrane in a solution containing PPy and PMo 12O 3- 40. The reversibility of ...A novel modified electrode was prepared by electrochemicaly cycling scanning the glass carbon electrode covered with a macroporous alumina membrane in a solution containing PPy and PMo 12O 3- 40. The reversibility of the cyclic voltammograms was improved obviously. The remarkable advantage of the modified electrode was the high sensitivity and favorable electrocatalytic behavior toward NO - 2. The peak current increased linearly with the concentration of NO - 2 in the range of 8.0×10 -7—0.01 mol/L. The detection limit of NO - 2 was 1.0×10 -9 mol/L. The polyoxometalates nanopaticles modified electrode exhibited almost the same electrochemical behavior after 7 d. It is indicated that the PMo 12-PPy/AGCE has a good reproducibility, stability and wide linearity range.展开更多
The interaction of oxide film with molten flux during aluminum brazing has been studied by means of X-ray powder diffraction. The following conclusions have been deduced: The swell- ing of aluminum oxide film is cause...The interaction of oxide film with molten flux during aluminum brazing has been studied by means of X-ray powder diffraction. The following conclusions have been deduced: The swell- ing of aluminum oxide film is caused by Li^+ inserting into the vacancies of octahedral or tetrahedral structure of 0 atom skeleton in у-Al_2O_3 . The strength of oxide film decreases as the crytallinity increases by the treating of flux containing LiF.展开更多
文摘A novel modified electrode was prepared by electrochemicaly cycling scanning the glass carbon electrode covered with a macroporous alumina membrane in a solution containing PPy and PMo 12O 3- 40. The reversibility of the cyclic voltammograms was improved obviously. The remarkable advantage of the modified electrode was the high sensitivity and favorable electrocatalytic behavior toward NO - 2. The peak current increased linearly with the concentration of NO - 2 in the range of 8.0×10 -7—0.01 mol/L. The detection limit of NO - 2 was 1.0×10 -9 mol/L. The polyoxometalates nanopaticles modified electrode exhibited almost the same electrochemical behavior after 7 d. It is indicated that the PMo 12-PPy/AGCE has a good reproducibility, stability and wide linearity range.
文摘The interaction of oxide film with molten flux during aluminum brazing has been studied by means of X-ray powder diffraction. The following conclusions have been deduced: The swell- ing of aluminum oxide film is caused by Li^+ inserting into the vacancies of octahedral or tetrahedral structure of 0 atom skeleton in у-Al_2O_3 . The strength of oxide film decreases as the crytallinity increases by the treating of flux containing LiF.