This study is devoted to the experimental validation of the multi-type sensor placement and response reconstruction method for structural health monitoring of long-span suspension bridges. The method for multi-type se...This study is devoted to the experimental validation of the multi-type sensor placement and response reconstruction method for structural health monitoring of long-span suspension bridges. The method for multi-type sensor placement and response reconstruction is briefly described. A test bed, comprising of a physical model and an updated finite element (P-E) model of a long-span suspension bridge is also concisely introduced. The proposed method is then applied to the test bed; the equation of motion of the test bed subject to ground motion, the objective function for sensor location optimization, the principles for mode selection and multi-type response reconstruction are established. A numerical study using the updated FE model is performed to select the sensor types, numbers, and locations. Subsequently, with the identified sensor locations and some practical considerations, fiber Bragg grating (FBG) sensors, laser displacement transducers, and accelerometers are installed on the physical bridge model. Finally, experimental investigations are conducted to validate the proposed method. The experimental results show that the reconstructed responses using the measured responses from the limited number of multitype sensors agree well with the actual bridge responses. The proposed method is validated to be feasible and effective for the monitoring of structural behavior of longspan suspension bridges.展开更多
雷击是影响±500 k V直流架空输电线路运行的重要因素,±500 k V直流线路避雷器的挂网试运行成功,为直流线路防雷改造提供了有效技术手段,但大规模的工程应用仍是空白。笔者结合±500 k V江城线直流线路避雷器安装项目,研究...雷击是影响±500 k V直流架空输电线路运行的重要因素,±500 k V直流线路避雷器的挂网试运行成功,为直流线路防雷改造提供了有效技术手段,但大规模的工程应用仍是空白。笔者结合±500 k V江城线直流线路避雷器安装项目,研究了±500 k V直流线路避雷器选型、选点原则,给出了不同塔型下直流线路避雷器的安装方案,并提出直线塔宜采用悬挂式安装方案,耐张塔宜采用地面支柱式安装方案。运行数据表明,笔者提出的±500 k V直流线路避雷器选型、选点原则防雷改造效果明显,安装方案达到线路安全运行要求,对±500 k V直流线路避雷器的推广应用和在运直流线路防雷改造工作具有重要的实践和借鉴意义。展开更多
文摘This study is devoted to the experimental validation of the multi-type sensor placement and response reconstruction method for structural health monitoring of long-span suspension bridges. The method for multi-type sensor placement and response reconstruction is briefly described. A test bed, comprising of a physical model and an updated finite element (P-E) model of a long-span suspension bridge is also concisely introduced. The proposed method is then applied to the test bed; the equation of motion of the test bed subject to ground motion, the objective function for sensor location optimization, the principles for mode selection and multi-type response reconstruction are established. A numerical study using the updated FE model is performed to select the sensor types, numbers, and locations. Subsequently, with the identified sensor locations and some practical considerations, fiber Bragg grating (FBG) sensors, laser displacement transducers, and accelerometers are installed on the physical bridge model. Finally, experimental investigations are conducted to validate the proposed method. The experimental results show that the reconstructed responses using the measured responses from the limited number of multitype sensors agree well with the actual bridge responses. The proposed method is validated to be feasible and effective for the monitoring of structural behavior of longspan suspension bridges.
文摘雷击是影响±500 k V直流架空输电线路运行的重要因素,±500 k V直流线路避雷器的挂网试运行成功,为直流线路防雷改造提供了有效技术手段,但大规模的工程应用仍是空白。笔者结合±500 k V江城线直流线路避雷器安装项目,研究了±500 k V直流线路避雷器选型、选点原则,给出了不同塔型下直流线路避雷器的安装方案,并提出直线塔宜采用悬挂式安装方案,耐张塔宜采用地面支柱式安装方案。运行数据表明,笔者提出的±500 k V直流线路避雷器选型、选点原则防雷改造效果明显,安装方案达到线路安全运行要求,对±500 k V直流线路避雷器的推广应用和在运直流线路防雷改造工作具有重要的实践和借鉴意义。