The new catalytic kinetic spectrophotometric method for Au(III) determination was developed and validated. It was based on the catalytic effect of gold on the oxidation of sudan red III by ammonium peroxodisulfate ...The new catalytic kinetic spectrophotometric method for Au(III) determination was developed and validated. It was based on the catalytic effect of gold on the oxidation of sudan red III by ammonium peroxodisulfate ((NH4)2S2O8) with nitrilo triacetic acid as an activator in microemulsion and H2SO4 medium. Under optimum conditions, there was the linearity of the calibration curve in the concentration range from 0 to 20 μg/L Au(Ⅲ) at 520 nm. The relative standard deviation was 3.0% with a correlation coefficient of 0.9986. The detection limit achieved was 9.75 × 10^-5 μg/mL. A new method using a column packed with sulfhydryl dextrose gel (SDG) as a solid-phase extractant has been developed for the preconcentration and separation of Au(Ⅲ) ions. The method has been applied to the determination of trace gold with satisfactory results.展开更多
A DNA biosensor with [Ru(DA-bpy)3]Cl2(DA-bpy:4,4'-diamino-2,2'-bipyridine) (RuL) as the electrochemical probe was prepared on pyrolytic graphite electrode (PGE) through the supramolecular interaction betwee...A DNA biosensor with [Ru(DA-bpy)3]Cl2(DA-bpy:4,4'-diamino-2,2'-bipyridine) (RuL) as the electrochemical probe was prepared on pyrolytic graphite electrode (PGE) through the supramolecular interaction between RuL complex and DNA template. Cyclic voltammetry of RuL-DNA film showed a pair of stable and reversible peaks corresponding to the Ru(Ⅲ)/Ru(Ⅲ) redox potential of-0.165 V versus AglAgCl in pa 7.4 0.1 mol·L^-1Tris-HCl. The electron transfer was expected across the double-strand DNA by an "electron tunneling" mechanism. When the DNA biosensor was immerged in gold (Ⅲ) buffer solution, the current peak signal (I) of the RuL-DNA supramolecular depressed and △I was linear in the concentration range of Au ion from 1×10^-7 to 2×10^-5 mol·L^-1 with a regression coefficient of 0.9879. The detection limit was 5×10^-8 mol·L^-1. The developed procedures were applied to the analysis of synthetic samples of real materials with good sensitivity and selectivity.展开更多
文摘The new catalytic kinetic spectrophotometric method for Au(III) determination was developed and validated. It was based on the catalytic effect of gold on the oxidation of sudan red III by ammonium peroxodisulfate ((NH4)2S2O8) with nitrilo triacetic acid as an activator in microemulsion and H2SO4 medium. Under optimum conditions, there was the linearity of the calibration curve in the concentration range from 0 to 20 μg/L Au(Ⅲ) at 520 nm. The relative standard deviation was 3.0% with a correlation coefficient of 0.9986. The detection limit achieved was 9.75 × 10^-5 μg/mL. A new method using a column packed with sulfhydryl dextrose gel (SDG) as a solid-phase extractant has been developed for the preconcentration and separation of Au(Ⅲ) ions. The method has been applied to the determination of trace gold with satisfactory results.
基金This study is financially supported by the National Natural Science Foundation of China (No. 60508012)the Natural Sci-ence Foundation of Zhejiang Province (No. Y106725)+1 种基金the Natural Science Foundation of Ningbo (No. 2006A610048)the Scientific and Technological Project Funding of Zhejiang Province (No. 2006C31040).
文摘A DNA biosensor with [Ru(DA-bpy)3]Cl2(DA-bpy:4,4'-diamino-2,2'-bipyridine) (RuL) as the electrochemical probe was prepared on pyrolytic graphite electrode (PGE) through the supramolecular interaction between RuL complex and DNA template. Cyclic voltammetry of RuL-DNA film showed a pair of stable and reversible peaks corresponding to the Ru(Ⅲ)/Ru(Ⅲ) redox potential of-0.165 V versus AglAgCl in pa 7.4 0.1 mol·L^-1Tris-HCl. The electron transfer was expected across the double-strand DNA by an "electron tunneling" mechanism. When the DNA biosensor was immerged in gold (Ⅲ) buffer solution, the current peak signal (I) of the RuL-DNA supramolecular depressed and △I was linear in the concentration range of Au ion from 1×10^-7 to 2×10^-5 mol·L^-1 with a regression coefficient of 0.9879. The detection limit was 5×10^-8 mol·L^-1. The developed procedures were applied to the analysis of synthetic samples of real materials with good sensitivity and selectivity.