期刊文献+

肝脏CT灌注成像的研究进展 被引量:21

CT perfusion imaging in liver: a further study
下载PDF
导出
摘要 CT灌注成像是基于核医学计算器官血流量的原理而发展起来的一种新兴技术。它能反映组织、器官的血流动力学状态 ,属于功能成像的范畴。对肝脏的灌注参数进行定量有助于在形态学变化之前发现肝脏的病变 ,具有广泛的临床应用前景。本文综述了肝脏CT灌注成像的基本原理、方法以及各种肝脏病变的灌注成像特点。 CT perfusion imaging is a new developing technique,which is based on the principle of calculating blood flow used in nuclear medicine. It belongs to functional imaging and can define hemodynamics of tissue or organs. Assessment of hepatic perfusion parameters is helpful to find liver disease before structural changes. This article is to review the basic principles of hepatic perfusion CT,imaging method and perfusion characteristics of various hepatic diseases.
出处 《中国医学影像技术》 CSCD 2004年第2期298-301,共4页 Chinese Journal of Medical Imaging Technology
关键词 体层摄影术 X线计算机 灌注 肝脏 血流动力学 Tomography,X-ray computed Perfusion Liver Hemodynamics
  • 相关文献

参考文献21

  • 1[1]Eastwood JD,Lev MH,Azhari T,et al. CT perfusion scanning with deconvolution analysis:pilot study in patients with acute middle cerebral artery stroke [J]. Radiology,2002,222(1):227-236. 被引量:1
  • 2[2]Furukawa M,Kashiwagi S,Matsunaga N,et al. Evaluation of cerebral perfusion parameters measured by perfusion CT in chronic cerebral ischemia: comparison with Xenon CT [J]. J Comput Assist Tomogr,2002,26(2):272-278. 被引量:1
  • 3[3]Miles KA,Heyball MP,Dixon AK,et al. Functional images of hepatic perfusion obtained with dynamic CT [J]. Radiology,1993,188(2):405-411. 被引量:1
  • 4[4]Blomley MJK,Coulden R,Dawson P,et al. Liver perfusion studied with ultrafast CT [J]. J Comput Assist Tomogr,1995,19(3):424-433. 被引量:1
  • 5[5]Materne R,Van Beers BE,Smith AM,et al. Non-invasive quantification of liver perfusion with dynamic computed tomography and a dual-input one-compartmental model [J]. Clin Sci,2000,99(6):517-525. 被引量:1
  • 6[6]Cuenod CA,Leconte I,Siauve N,et al. Early changes in liver perfusion caused by occult metastases in rats: detection with quantitative CT [J]. Radiology,2001,218(2):556-561. 被引量:1
  • 7[7]Miles KA. Measurement of tissue perfusion by dynamic computed tomography [J].Br J Radiol,1991,64(761):409-412. 被引量:1
  • 8[8]Hindmarsh T. Elimination of water-soluble contrast media from the subarachnoid space: investigation with computed tomography [J]. Acta Radiol,1975,346(Suppl):45-49. 被引量:1
  • 9[9]Axel L.Cerebral blood flow determination by rapid-sequence computed tomography [J]. Radiology,1980,137(3):679-686. 被引量:1
  • 10[10]Bader TR,Herneth AM,Blaicher W,et al. Hepatic perfusion after liver transplantation: noninvasive measurement with dynamic single-section CT [J]. Radiology,1998,209(1):129-134. 被引量:1