期刊文献+

双层铠装海底光缆抗拉强度的计算 被引量:12

Calculation of tensile-strength of submarine fiber opticcable with double layer armour
下载PDF
导出
摘要  通过对海底光缆双层铠装结构的分析计算,推导出了计算双层铠装海底光缆抗拉强度的数学模型,提出了一种确定光缆铠装钢丝结构的方法,并用MATLAB软件做出了计算程序,将计算结果与一些光缆参数进行了对比。该数学模型对海底光缆的生产具有一定的指导意义。 Through analyzing and calculation of the double layer armouring structure of submarine optical fiber cable (SOFC), the mathematic model for calculating tensile strength of SOFC with double layer armour is derived, and a method for determining the structure of steel-wire armour for SOFC is proposed. In addition the calculation procedure is made up with MATLAB software, and the calculation results are compared with parameters of some SOFCs. The present mathematic model offers certain guiding function for the production of SOFC.
出处 《光纤与电缆及其应用技术》 2004年第1期28-31,共4页 Optical Fiber & Electric Cable and Their Applications
关键词 海底光缆 双层铠装 抗拉强度 数学模型 钢丝结构 MATLAB软件 submarine fiber optic cable double layer armour tensile-strength