期刊文献+

Feasibility of real-time magnetic resonance imaging-guided endomyocardial biopsies:An in-vitro study

Feasibility of real-time magnetic resonance imaging-guided endomyocardial biopsies:An in-vitro study
下载PDF
导出
摘要 AIM: To investigate if magnetic resonance(MR)-guided biopsy can improve the performance and safety of such procedures. METHODS: A novel MR-compatible bioptome was evaluated in a series of in-vitro experiments in a 1.5T magnetic resonance imaging(MRI) system. The bioptome was inserted into explanted porcine and bovine hearts under real-time MR-guidance employing a steady state free precession sequence. The artifact produced by the metal element at the tip and the signal voids caused by the bioptome were visually tracked for navigation and allowed its constant and precise localization. RESULTS: Cardiac structural elements and the target regions for the biopsy were clearly visible. Our method allowed a significantly better spatial visualization of the bioptoms tip compared to conventional X-ray guidance. The specific device design of the bioptome avoided inducible currents and therefore subsequent heating. The novel MR-compatible bioptome provided a superior cardiovascular magnetic resonance(imaging) soft-tissue visualization for MR-guided myocardial biopsies. Not at least the use of MRI guidance for endomyocardial biopsies completely avoided radiation exposure for both patients and interventionalists.CONCLUSION: MRI-guided endomyocardial biopsies provide a better than conventional X-ray guided navigation and could therefore improve the specificity and reproducibility of cardiac biopsies in future studies. AIM: To investigate if magnetic resonance(MR)-guided biopsy can improve the performance and safety of such procedures. METHODS: A novel MR-compatible bioptome was evaluated in a series of in-vitro experiments in a 1.5T magnetic resonance imaging(MRI) system. The bioptome was inserted into explanted porcine and bovine hearts under real-time MR-guidance employing a steady state free precession sequence. The artifact produced by the metal element at the tip and the signal voids caused by the bioptome were visually tracked for navigation and allowed its constant and precise localization. RESULTS: Cardiac structural elements and the target regions for the biopsy were clearly visible. Our method allowed a significantly better spatial visualization of the bioptoms tip compared to conventional X-ray guidance. The specific device design of the bioptome avoided inducible currents and therefore subsequent heating. The novel MR-compatible bioptome provided a superior cardiovascular magnetic resonance(imaging) soft-tissue visualization for MR-guided myocardial biopsies. Not at least the use of MRI guidance for endomyocardial biopsies completely avoided radiation exposure for both patients and interventionalists.CONCLUSION: MRI-guided endomyocardial biopsies provide a better than conventional X-ray guided navigation and could therefore improve the specificity and reproducibility of cardiac biopsies in future studies.
出处 《World Journal of Cardiology》 CAS 2015年第7期415-422,共8页 世界心脏病学杂志(英文版)(电子版)
基金 Supported by The German Research Foundation(KA493/6_1)
关键词 Endomyocardial biopsy Cardiovascular MAGNETIC resonance(imaging) MAGNETIC RESONANCE imaging-guided interventions REAL-TIME IMAGING Endomyocardial biopsy Cardiovascular magnetic resonance(imaging) Magnetic resonance imaging-guided interventions Real-time imaging
  • 相关文献

参考文献17

  • 1Oxner, Christopher R,Vora, Lalit,Yim, John,Kruper, Laura,Ellenhorn, Joshua D I.Magnetic Resonance Imaging-Guided Breast Biopsy in Lesions Not Visualized by Mammogram or Ultrasound[J]. EN . 2012 (10) 被引量:1
  • 2Jennifer A. Dickerson,Subha V. Raman,Peter M. Baker,Carl V. Leier.Relationship of Cardiac Magnetic Resonance Imaging and Myocardial Biopsy in the Evaluation of Nonischemic Cardiomyopathy[J]. Congestive Heart Failure . 2012 (1) 被引量:1
  • 3Andrew J. Einstein.Effects of Radiation Exposure From Cardiac Imaging[J]. Journal of the American College of Cardiology . 2012 (6) 被引量:1
  • 4E Neufeld,S Kühn,G Szekely,N Kuster.Measurement, simulation and uncertainty assessment of implant heating during MRI[J]. Physics in Medicine and Biology . 2009 (13) 被引量:1
  • 5Heart Failure Society Of America.Executive Summary: HFSA 2006 Comprehensive Heart Failure Practice Guideline[J]. Journal of Cardiac Failure . 2006 (1) 被引量:1
  • 6Jared W. Magnani,G William Dec.Myocarditis: Current Trends in Diagnosis and Treatment[J]. Circulation . 2006 (6) 被引量:1
  • 7Magnetic Resonance-guided Transcortical Biopsy of Bone Marrow Lesions Using a Magnetic Resonance Imaging-compatible Piezoelectric Power Drill: Preliminary Experience[J]. Investigative Radiology . 2003 (3) 被引量:1
  • 8Cooper LT,Baughman KL,Feldman AM,Frustaci A,Jessup M,Kuhl U,Levine GN,Narula J,Starling RC,Towbin J,Virmani R.The role of endomyocardial biopsy in the management of cardiovascular disease:a scientific statement from the American Heart Association,the American College of Cardiology,and the European Society of Cardiology. Circulation . 2007 被引量:1
  • 9Hunt SA,Abraham WT,Chin MH,Feldman AM,Francis GS,Ganiats TG,Jessup M,Konstam MA,Mancini DM,Michl K,Oates JA,Rahko PS,Silver MA,Stevenson LW,Yancy CW.2009focused update incorporated into the ACC/AHA 2005 Guidelines for the Diagnosis and Management of Heart Failure in Adults:a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines:developed i. Circulation . 2009 被引量:1
  • 10Mattei Eugenio,Triventi Michele,Calcagnini Giovanni,Censi Federica,Kainz Wolfgang,Mendoza Gonzalo,Bassen Howard I,Bartolini Pietro.Complexity of MRI induced heating on metallic leads: experimental measurements of 374 configurations. Biomedical Engineering . 2008 被引量:1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部