期刊文献+

Grey-scale sonography and sonoelastography for diagnosing carpal tunnel syndrome 被引量:5

Grey-scale sonography and sonoelastography for diagnosing carpal tunnel syndrome
下载PDF
导出
摘要 Carpal tunnel syndrome(CTS) is a common peripheral entrapment neuropathy of the median nerve at wrist level, and is thought to be caused by compression of the median nerve in the carpal tunnel. There is no standard quantitative reference for the diagnosis of CTS. Greyscale sonography and sonoelastography(SEL) have been used as diagnostic tools. The most commonly agreed findings in grey-scale sonography for the diagnosis of CTS is enlargement of the median nerve cross-sectional area(CSA). Several authors have assessed additional parameters. "Delta CSA" is the difference between the proximal median nerve CSA at the pronator quadratus and the maximal CSA within the carpal tunnel. The "CSA ratio" is the ratio of CSA in the carpal tunnel to the CSA at the mid forearm. These additional parameters showed better diagnostic accuracy than CSA measurement alone. Recently, a number of studies have investigated the elasticity of the median nerve using SEL, and have shown that this also has diagnostic value, as it was significantly stiffer in CTS patients compared to healthy volunteers. In this review, we summarize the usefulness of grey-scale sonography and SEL in diagnosing CTS. Carpal tunnel syndrome (CTS) is a common peripheral entrapment neuropathy of the median nerve at wrist level, and is thought to be caused by compression of the median nerve in the carpal tunnel. There is no standard quantitative reference for the diagnosis of CTS. Grey-scale sonography and sonoelastography (SEL) have been used as diagnostic tools. The most commonly agreed findings in grey-scale sonography for the diagnosis of CTS is enlargement of the median nerve cross-sectional area (CSA). Several authors have assessed additional parameters. “Delta CSA” is the difference between the proximal median nerve CSA at the pronator quadratus and the maximal CSA within the carpal tunnel. The “CSA ratio” is the ratio of CSA in the carpal tunnel to the CSA at the mid forearm. These additional parameters showed better diagnostic accuracy than CSA measurement alone. Recently, a number of studies have investigated the elasticity of the median nerve using SEL, and have shown that this also has diagnostic value, as it was significantly stiffer in CTS patients compared to healthy volunteers. In this review, we summarize the usefulness of grey-scale sonography and SEL in diagnosing CTS.
出处 《World Journal of Radiology》 CAS 2016年第3期281-287,共7页 世界放射学杂志(英文版)(电子版)
关键词 CARPAL tunnel syndrome CROSS-SECTIONAL area GRAY-SCALE SONOGRAPHY Diagnosis MEDIAN nerve SONOELASTOGRAPHY Elasticity Carpal tunnel syndrome Cross-sectional area Gray-scale sonography Diagnosis Median nerve Sonoelastography Elasticity
  • 相关文献

参考文献68

  • 1Tajika T,Kobayashi T,Yamamoto A,et al.Diagnostic utility of sonography and correlation between sonographic and clinical findings in patients with carpal tunnel syndrome. Journal of Ultrasound in Medicine . 2013 被引量:1
  • 2Mohammad Ghasemi-rad,Emad Nosair,Andrea Vegh,Afshin Mohammadi,Adam Akkad,Emal Lesha,Mohammad Hossein Mohammadi,Doaa Sayed,Ali Davarian,Tooraj Maleki-Miyoab,Anwarul Hasan.A handy review of carpal tunnel syndrome:From anatomy to diagnosis and treatment[J].World Journal of Radiology,2014,6(6):284-300. 被引量:24
  • 3A. Klauser,H. Miyamoto,C. Martinoli,A. Tagliafico,J. Szantkay,G. Feuchtner,W. Jaschke.??Sonoelastografische Befunde nach Karpaltunnel Injektion(J)Ultraschall in Med . 2015 被引量:1
  • 4Chin Chin Ooi,Siew Kune Wong,Agnes B. H. Tan,Andrew Y. H. Chin,Rafidah Abu Bakar,Shy Yunn Goh,P. Chandra Mohan,Robert T. J. Yap,Meng Ai Png.??Diagnostic criteria of carpal tunnel syndrome using high-resolution ultrasonography: correlation with nerve conduction studies(J)Skeletal Radiology . 2014 (10) 被引量:1
  • 5Yuichi Yoshii,Tomoo Ishii,Fumihiko Etou,Shinsuke Sakai,Toshikazu Tanaka,Naoyuki Ochiai.??Reliability of Automatic Vibratory Equipment for Ultrasonic Strain Measurement of the Median Nerve(J)Ultrasound in Medicine & Biology . 2014 (10) 被引量:1
  • 6Yuichi Yoshii,Tomoo Ishii,Toshikazu Tanaka,Wen-lin Tung,Shinsuke Sakai.??Detecting Median Nerve Strain Changes with Cyclic Compression Apparatus: A Comparison of Carpal Tunnel Syndrome Patients and Healthy Controls(J)Ultrasound in Medicine & Biology . 2014 被引量:1
  • 7Geraldine A.K.B. Vanderschueren,Vera E.W.H. Meys,Roy Beekman.??Doppler sonography for the diagnosis of carpal tunnel syndrome: A critical review(J)Muscle Nerve . 2014 (2) 被引量:1
  • 8Gunes Orman,Serkan Ozben,Nergiz Huseyinoglu,Mahmut Duymus,Keziban Gunce Orman.??Ultrasound Elastographic Evaluation in the Diagnosis of Carpal Tunnel Syndrome: Initial Findings(J)Ultrasound in Medicine & Biology . 2013 (7) 被引量:1
  • 9Yongbum Park,Ji-Hae Lee,Ki Deok Park,Jae Ki Ahn,Jaehyun Park,Haemi Jee.??Ultrasound-Guided vs. Fluoroscopy-Guided Caudal Epidural Steroid Injection for the Treatment of Unilateral Lower Lumbar Radicular Pain: A Prospective, Randomized, Single-Blind Clinical Study(J)American Journal of Physical Medicine & Rehabilitation . 2013 (7) 被引量:1
  • 10John R. Fowler,Mitchell G. Maltenfort,Asif M. Ilyas.??Ultrasound as a First-line Test in the Diagnosis of Carpal Tunnel Syndrome: A Cost-effectiveness Analysis(J)Clinical Orthopaedics and Related Research? . 2013 (3) 被引量:1

二级参考文献1

共引文献28

同被引文献17

引证文献5

二级引证文献28

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部