摘要
对北京某地源热泵项目的运行工况进行了监测,分析了土壤温度、空调侧及地源侧供回水温度、耗电量、每延米换热量等参数的变化。测试结果显示:土壤温度随运行时间的变化具有明显的季节性,在(15±10)℃内波动,系统运行较稳定;冬、夏季每延米换热量的平均值分别约为40 W/m和66 W/m;冬季供热耗电量约占全年总耗电量的41.2%;项目平均每年节省327.18 t标准煤;在寒冷地区使用地源热泵系统节能效果及经济效益显著。
Monitors the operating conditions of a ground-source heat pump project in Beijing,and analyses the changes of soil temperature,supply and return water temperature in air conditioning side and ground side,power consumption and heat transfer capacity per meter.The test results show that the soil temperature varies seasonally with the running time,fluctuating within(15±10)℃,and the system runs steadily.The average heat transfer capacity per meter in winter and summer is about 40 W/m and 66 W/m,respectively.The heating consumption in winter is about 41.2%of the total consumption in the whole year.The project can save an average standard coal of 327.18 t per year,and the energy saving effect and economic benefits of ground-source heat pump system in cold zones are remarkable.
作者
金光
王瑾瑾
毕文明
赵雪茹
王冰
张之强
Jin Guang;Wang Jinjin;Bi Wenming;Zhao Xueru;Wang Bing;Zhang Zhiqiang(Inner Mongolia University of Science and Technology,Baotou,Inner Mongolia,China)
出处
《暖通空调》
2019年第9期68-71,共4页
Heating Ventilating & Air Conditioning
基金
内蒙古自治区科技创新引导奖励资金项目(编号:2017CXYD-1)
内蒙古自治区自然科学基金资助项目(编号:2015MS0561,2016BS0512)
2017年内蒙古自治区应对气候变化及低碳发展专项资金项目(编号:2017NMFG015)
关键词
地源热泵工程
土壤温度
供回水温度
换热量
耗电量
节能环保
ground-source heat pump project
soil temperature
supply and return water temperature
heat transfer capacity
power consumption
energy saving and environmental protection