针对湖北汉新发电有限公司凝结水泵变频运行存在的问题,在机组大修期间采取了一系列控制策略优化措施,相关数据表明优化后凝结水泵变频运行更具安全性和经济性。
Aiming at the existing problem of variable-frequency operation control for condensate pump in Hubei Hanxin Power Generation Co.,Ltd,a series of control strategy optimization measures were taken to solve the problem during unit maintenance,these practical operation figures showed that variable-frequency operation of condensate pump is more safety and economy after optimization.
出处
《湖北电力》
2015年第6期59-61,共3页
Hubei Electric Power
关键词
凝结水泵
变频
控制
优化
condensate pump
variable-frequency
control
optimization