摘要
本研究利用文献研究法与案例研究法对木结构建筑技术与被动式超低能耗建筑技术的集成与运用进行深入研究。首先从节能环保、保温隔热、气密适宜3方面分析两种技术集成运用的价值,随后以山东省菏泽市装配式示范园50号楼地上两层+1层阁楼的轻型木结构项目为例,对该项目木结构建筑技术与被动式超低能耗建筑技术的集成运用进行探究,并从气密性、隔热性、低能耗3方面检测分析两种技术集成化运用效果。
The full text use of literature research method and case study method of wood structure building technology and passive ultra-low energy consumption building technology integration and application of further research.First from energy conservation and environmental protection,heat insulation,thermal insulation suitable three aspects analysis of the value of two technology integration,then in Heze city prefabricated demonstration garden 50#two+a attic of light wooden structure project,for example,the project wooden structure construction technology and passive ultra-low energy consumption building technology integration to explore,and from three aspects of air tightness,heat insulation,low energy consumption detection analysis of two technology integration application effect.
出处
《建筑技术开发》
2024年第10期150-152,共3页
Building Technology Development
基金
2023年度山东省住房城乡建设科技计划项目(121号)。
关键词
木结构
被动式建筑
超低能耗
建筑技术
wood structure
passive building
ultra-low energy consumption