期刊文献+

基于反射光度法的干化学检测技术的研究

Research on Dry Chemical Detection Technology Based on Reflectance Photometry
下载PDF
导出
摘要 针对反射光度法的干化学检测中,因检测样品反射光信号的发散和多层膜干片试纸内部存在多重内反射,导致检测稳定性和准确性不足的问题,设计了一种基于积分球的干化学反射光度法检测系统。首先,增设积分球装置,可减少信号的发散与流失并均匀检测样品的反射光信号,提高检测的稳定性;其次,进行Light Tools光学仿真分析,并建立积分球检测模型;再次,基于Williams-Clapper方程对多重内反射导致的反射密度的误差进行修正以提高检测的准确性。实验验证:所开发的基于积分球的干化学反射光度法检测系统提高了检测系统的稳定性和准确性。 In response to the issues of insufficient stability and accuracy in dry chemical detection using reflectance photometry,caused by the divergence and multiple internal reflections of the reflected light signal from the sample and the multilayer dry film test strip,a dry chemical reflectance photometry detection system based on an integrating sphere is designed.Firstly,an integrating sphere device is incorporated to reduce signal divergence and loss,ensuring even detection of the sample's reflected light signal and improving detection stability.Secondly,Light Tools optical simulation analysis is performed,and an integrating sphere detection model is established.Thirdly,the Williams-Clapper equation is employed to correct the error in reflectance density caused by multiple internal reflections,enhancing detection accuracy.Experimental validation demonstrates that the developed integrating sphere-based dry chemical reflectance photometry detection system improves the stability and accuracy of the detection system.
作者 卢堂红 黄菊花 黄春江 冯帅丁 游凌峰 LU Tanghong;HUANG Juhua;HUANG Chunjiang;FENG Shuaiding;YOU Lingfeng(Institute of Medical Devices,College of Advanced Manufacturing,Nanchang University,Nanchang,330036)
出处 《中国医疗器械杂志》 2024年第2期160-166,共7页 Chinese Journal of Medical Instrumentation
关键词 反射光度法 多重内反射 积分球 Williams-Clapper方程 reflectance photometry multiple internal reflections integrating sphere Williams-Clapper equation
  • 相关文献

参考文献8

二级参考文献28

  • 1黄昊,陈卫彬.普通湿式生化分析仪与干式生化分析仪的比较分析[J].医学检验与临床,2008,20(1):4-5. 被引量:5
  • 2杨树德.当代临床检验中的固相化学[J].国外医学(临床生物化学与检验学分册),1995,16(3):98-102. 被引量:9
  • 3焦晋兰,王福生.放免工作中乳糜血的处理方法[J].河南外科学杂志,2006,12(2):83-84. 被引量:5
  • 4St. Joseph Hospital, Kirkwood, MO. New technologies for laboratory productivity. J Healthc Mater Manage. 1994, 12(3) :30-34. 被引量:1
  • 5Lapekas P. New technologies for laboratory productivity. J Healthc Mater Manage. 1994, 12(3) :30 - 34. 被引量:1
  • 6Yamada T, Nishino S, Takubo T etc. Simple high - density lipoprotein cholesterol assay based on dry chemistry. Clin Chim Acta. 2002,320( 1 - 2) :79 - 88. 被引量:1
  • 7D. Power, On the Spot News (For Users of Diagnostic Product From Kodak) 1990,2(1):1. 被引量:1
  • 8Terashima K, Tatsumi N. Compact dry chemistry instruments.Southeast Asian J Trop Med Public Health. 1999,3:122- 9. 被引量:1
  • 9Rubin DA, McMurray RG, Harrell JS etc. Accuracy of three dry- chemistry methods for lipid profiling and risk factor classification. Int J Sport Nutr Exerc Metab. 2003, 13(3):358-68. 被引量:1
  • 10Sutton A, Dawson H, Hoff B, Grift E, Shoukri M. Analyte comparisons between 2 clinical chemistry analyzers. Can Vet J.1999,40(4) :255 - 60. 被引量:1