摘要
目的 分析新型板钉互锁系统内固定治疗AO-B、C型股骨远端骨折的疗效。方法 回顾性分析自2019-01—2022-01诊治的61例AO-B、C型股骨远端骨折,其中36例采用新型板钉互锁系统固定(改进组),25例采用常规单切口股骨远端双钢板固定(常规组)。比较两组手术时间、术中出血量、住院时间、完全负重时间,以及术后膝关节活动度、HSS膝关节功能评分、骨折复位质量等指标。结果 所有患者均获得随访,随访时间8~36个月,平均25个月。改进组手术时间、术中出血量、术中透视次数、术后引流出血量均优于常规组,差异有统计学意义(P<0.05),但两组住院时间差异无统计学意义(P>0.05)。改进组术后下床时间、完全负重时间均早于常规组,而且末次随访膝关节活动度、HSS膝关节功能评分也高于常规组,差异均有统计学意义(P<0.05)。两组末次随访短缩畸形、内外畸形发生率差异无统计学意义(P>0.05)。末次随访两组骨折复位质量差异无统计学意义(P>0.05),但改进组骨折愈合时间早于常规组,差异有统计学意义(P<0.05)。结论 新型板钉互锁系统内固定治疗AO-B、C型股骨远端骨折的疗效满意,具有损伤小、手术效率高、术中透视次数少、术后恢复快等优点,值得临床推广应用。
Objective To analyze the efficacy of a new interlocking system of plate and nail for AO type B,C distal femoral fractures.Methods A retrospective analysis was conducted on 61 cases of AO type B,C distal femoral fractures from January 2019 to January 2022.Thirty six cases were fixed by a new interlocking system of plates and nails(improved group)while 25 cases were fixed with conventional single incision dual plate fixation of distal femoral fractures(conventional group).The surgi⁃cal time,intraoperative bleeding,hospital stay,complete weight-bearing time,as well as postoperative knee joint range of mo⁃tion,HSS knee joint function score,and fracture reduction quality between the two groups were compared.Results All pa⁃tients were followed up for 8-36 months,with an average of 25 months.The surgical time,intraoperative bleeding,intraoperative fluoroscopy frequency,and postoperative drainage bleeding in the improvement group were all lower than those in the conven⁃tional group,with a statistically significant difference(P<0.05),but there was no statistically significant difference in hospital stay between the two groups(P>0.05).The improved group had earlier postoperative time to get out of bed and complete weight bearing than in the conventional group,and the last follow-up knee joint range of motion and HSS knee joint function score in the improvement group were also higher than those in the conventional group,with statistical significance(P<0.05).There was no statistically significant difference(P>0.05)in the incidence of shortening and internal and external deformities between the two groups during the last follow-up.There was no statistically significant difference in the quality of fracture reduction between the two groups during the last follow-up(P>0.05),but the fracture healing time in the improved group was earlier than that in the conventional group,with a statistically significant difference(P<0.05).Conclusion The new interlocking system of plate and nail for internal fixation in the treatment of
作者
吴咏德
陈波
伍伟飞
WU Yongde;CHEN Bo;WU Weifei(Department of Orthopedics,Yichang Central People’Hospital,Yichang,Hubei 443000,China;不详)
出处
《中国骨与关节损伤杂志》
2024年第2期128-132,共5页
Chinese Journal of Bone and Joint Injury
基金
湖北省自然科学基金(2023AFB1006)。
关键词
股骨远端骨折
板钉互锁系统
髓内钉
内固定
Distal femoral fracture
Plate interlocking system
Intramedullary nail fixation
Internal fixation