内蒙古地区数据中心热量管理的挑战和对策

The Challenge and Countermeasure of Thermal Management of Data Center in Inner Mongolia
下载PDF
导出
摘要 内蒙古地区的数据中心是国家“东数西算”工程的关键实践区域,但其热量管理在硬件设备与空间布局、建模与调度策略和热量模拟方法与平台等方面仍面临许多挑战。为使内蒙古数据中心可持续发展,提出了优化设备布局合理规划散热冷却机制、注重清洁能源利用优化运行调度策略和开发热量模拟仿真平台等数据中心热量管理应对策略。并进一步提出展望,即理想的数据中心热量模拟平台应具备数据中心运行状态模拟、轻量级的热模拟、人工智能集成仿真功能和大规模异构跨区域数据中心模仿能力等。 The data center in Inner Mongolia is an essential practice area for the national“Eastern Data and Western Computing”project,However,thermal management still has many challenges regarding building and equip⁃ment layout,modeling and scheduling strategies,and thermal simulation methods and platforms.In order to make the data center in Inner Mongolia sustainable,this paper proposes strategies for data center thermal management,such as optimizing the equipment layout,planning the heat dissipation and cooling mechanism,utilizing clean ener⁃gy,optimizing the operation and scheduling strategy,and developing the thermal simulation platform.This paper fur⁃ther shows the prospects of an ideal data center thermal simulation platform.The platform should have the simula⁃tion of the data center’s operation state,the lightweight thermal simulation,the integrated simulation function of arti⁃ficial intelligence,and the imitation ability of large-scale heterogeneous cross-regional data centers.
作者 宋杰 李丹阳 白丽丽 姜静清 SONG Jie;LI Danyang;BAI Lili;JIANG Jingqing(Software College,Northeastern University,Shenyang 112000,China;College of Computer Science and Technology,Inner Mongolia Minzu University,Tongliao 028043,China)
出处 《内蒙古民族大学学报(自然科学版)》 2024年第1期1-5,共5页 Journal of Inner Mongolia Minzu University:Natural Sciences
基金 国家自然科学基金项目(62162050)。
关键词 “双碳”目标 数字中国 数据中心 热量管理 “double carbon”target digital China data center thermal management
  • 相关文献

参考文献7

二级参考文献46

  • 1中国电子工程设计院.GB50174-2008电子信息系统机房设计规范[S].北京:中国计划出版社,2009. 被引量:28
  • 2云计算发展与政策论坛.数据中心能效测评指南[C].2012. 被引量:3
  • 3Environmental Protection Agency. Report to congress on server and data center energy efficiency [-R. Public Law 109-431. U S, 2007. 被引量:1
  • 4Sun H S, Lee S E. Case study of data centers' energy performance[J. Energy and Buildings, 2006,38 (5) . 522-533. 被引量:1
  • 5Koomy J G. Growth in data center electricity use 2005 to 2010 EEB/OL. E2011 http: /// www. analyticspress, eom/datacenters, html. 被引量:1
  • 6ASHRAE. ASHRAE TC 9.9 Thermal guidelines for data processing environments expanded data center classes and usage guidanceES, 2011. 被引量:1
  • 7Sharma R K, Bash C E, Patel R D. I)imensionless parameters for evaluation of thermal design and performance of large-scale data centersC// In 8th ASME/AIAA Joint Thermophysies and Heat Transfer Conference, 2002. 被引量:1
  • 8Herrlin M. Rack cooling effectiveness in data centers and teleeom central offices the rack cooling index (RCI)EGT// ASHRAE Trans, 2005,111(2) : 1 -11. 被引量:1
  • 9Cho J, Kim B S. Evaluation of air management system's thermal performance for superior cooling efficiency in high-density data centers[J. Energy and Buildings, 2011,43(9). 2145-2155. 被引量:1
  • 10王佳隽,吕智慧,吴杰,钟亦平.云计算技术发展分析及其应用探讨[J].计算机工程与设计,2010,31(20):4404-4409. 被引量:155

共引文献98

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部