民用建筑中常用蓄电池室及其爆炸危险性定义的讨论

Discussion on Common Battery Rooms and the Definition of Their Explosion Hazard in Civil Buildings
下载PDF
导出
摘要 针对土建设计时是否将蓄电池室定义为“爆炸危险场所”这一存在争议的问题,梳理国内外标准、规范对铅酸蓄电池室、锂离子蓄电池室的相关条文规定并进行总结,结合实际案例分析蓄电池可能引起“爆炸”的原因,提出设计建议。 In order to solve the controversial issue that whether battery room should be defined as a“hazardous area”in civil design,relevant provisions of domestic and foreign standards and codes for lead-acid battery rooms and lithium-ion battery rooms are sorted out and summarized,possible reasons for the explosion of battery are analyzed based on practical cases,and recommendations on design are proposed.
作者 金越 JIN Yue(Radio,Film&Television Design&Research Institute Co.,Ltd.,Beijing 100045,China)
出处 《建筑电气》 2024年第2期51-55,共5页 Building Electricity
关键词 不间断电源 蓄电池室 锂离子电池 阀控铅酸蓄电池 热失控 氢浓度 爆炸危险场所 通风装置 UPS battery room lithium-ion battery valve-regulated lead-acid battery thermal runaway hydrogen concentration hazardous area ventilation device