针对土建设计时是否将蓄电池室定义为“爆炸危险场所”这一存在争议的问题,梳理国内外标准、规范对铅酸蓄电池室、锂离子蓄电池室的相关条文规定并进行总结,结合实际案例分析蓄电池可能引起“爆炸”的原因,提出设计建议。
In order to solve the controversial issue that whether battery room should be defined as a“hazardous area”in civil design,relevant provisions of domestic and foreign standards and codes for lead-acid battery rooms and lithium-ion battery rooms are sorted out and summarized,possible reasons for the explosion of battery are analyzed based on practical cases,and recommendations on design are proposed.
作者
金越
JIN Yue(Radio,Film&Television Design&Research Institute Co.,Ltd.,Beijing 100045,China)
出处
《建筑电气》
2024年第2期51-55,共5页
Building Electricity
关键词
不间断电源
蓄电池室
锂离子电池
阀控铅酸蓄电池
热失控
氢浓度
爆炸危险场所
通风装置
UPS
battery room
lithium-ion battery
valve-regulated lead-acid battery
thermal runaway
hydrogen concentration
hazardous area
ventilation device