期刊文献+

F_(1)等级20 kg砝码测量审核实践

Practice of Measurement Audit for 20 kg Weight with F_(1)Grade
下载PDF
导出
摘要 为了验证某实验室砝码校准能力,开展砝码测量审核。以F_(1)等级20 kg砝码为例,介绍砝码测量审核申请流程、砝码校准过程、校准数据处理和测量审核结果分析。某实验室砝码测量审核结论为满意,表明该实验室的砝码校准能力满足要求,能开展砝码校准工作。 To verify the calibration capability of a certain laboratory's weights,a weight measurement audit was con⁃ducted.Taking the F_(1) grade 20 kg weight as an example,the paper introduces the application process for weight mea⁃surement audit,weight calibration process,processing of calibration data,and analysis of measurement audit results.The weight measurement audit conclusion of a certain laboratory is satisfactory,which indicates that the weight cali⁃bration capability of the laboratory meets the requirements and can carry out weight calibration work.
作者 彭冲 PENG Chong
出处 《铁道技术监督》 2024年第1期22-25,共4页 Railway Quality Control
关键词 砝码 测量审核 数据处理 Weight Measurement Audit Data Processing
  • 相关文献

参考文献4

二级参考文献2

共引文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史