期刊文献+

水产品中哈维氏弧菌等温快速检测方法优化及比较 被引量:3

Optimization and comparison of isothermal rapid detection methods for Vibrio harveyi in aquatic products
下载PDF
导出
摘要 目的 基于核酸等温扩增技术,建立荧光法、可视化环介导恒温扩增(loop-mediatedisothermal amplification,LAMP)和重组酶聚合酶扩增(recombinasepolymeraseamplification,RPA)快速检测哈维氏弧菌(Vibrio harveyi)的分析方法,并对方法进行优化和比较。方法 选择哈维氏弧菌toxR基因为特异靶标序列,分别设计了2组LAMP引物、3组RPA引物,对方法进行筛选。优化建立了荧光法LAMP、可视化LAMP、普通RPA3种等温扩增方法,对3种方法的特异性和灵敏度进行比较,并用模拟污染样本验证检测实际样品的灵敏度。结果 基于快速提取的哈维氏弧菌基因组DNA,本研究所建立的荧光法LAMP、可视化LAMP、普通RPA 3种等温扩增方法均具有良好的特异性,与同属及近属的细菌没有交叉反应。3种方法的灵敏度分别为5.27 fg/μL (1.99 fg/μL~0.93 pg/μL, 95%置信区间)、0.11 ng/μL、1.07 pg/μL;荧光LAMP和普通RPA对模拟污染样本的灵敏度分别为7 CFU/mL和97 CFU/mL。结论 本研究建立优化的3种等温快速检测方法结果准确、操作简单,扩增效率和灵敏度优于文献报道的同类方法,提高了哈维氏弧菌现场快速检测水平。 Objective To establish the analytical methods for rapid detection of Vibrio harveyi by fluorescence,visual loop-mediated isothermal amplification(LAMP)and recombinase polymerase amplification(RPA),based on the isothermal amplification technology of nucleic acid,and optimize and compare the methods.Methods The toxR gene of Vibrio harveyi was selected as the specific target sequence,2 sets of LAMP primers and 3 groups of RPA primers were designed,the primers were screened,and 3 kinds of isothermal amplification methods of fluorescence LAMP,visual LAMP and ordinary RPA were optimal establishment,the specificity and sensitivity of the 3 kinds of methods were compared,and the sensitivity of the actual sample was verified by simulated contaminated samples.Results Based on the rapidly extracted Vibrio harveyi genomic DNA,the 3 kinds of isothermal amplification methods of fluorescence LAMP,visual LAMP and ordinary RPA established in this paper had good specificity and had no cross-reactivity with bacteria of the same genus and related genus.The sensitivities of fluorescent LAMP,visual LAMP and ordinary RPA were 5.27 fg/μL(1.99 fg/μL-0.93 pg/μL,95%confidence interval),0.11 ng/μL,and 1.07 pg/μL,the sensitivities of fluorescent LAMP and ordinary RPA to simulated contaminated samples were 7 CFU/mL and 97 CFU/mL.Conclusion In this paper,the 3 kinds of optimized isothermal rapid detection methods have accurate results,simple operation,amplification efficiency and sensitivity than similar methods reported in literature,and improve the level of on-site rapid detection of Vibrio harveyi.
作者 仲瑶 贾惠齐 苏鹏 刘玉欣 孔昕荟 龚思颖 郑秋月 曹际娟 ZHONG Yao;JIA Hui-Qi;SU Peng;LIU Yu-Xin;KONG Xin-Hui;GONG Si-Ying;ZHENG Qiu-Yue;CAO Ji-Juan(Key Laboratory of Biotechnology and Bioresources Utilization of Ministry of Education,College of Life Science,Dalian Minzu University,Dalian 116600,China;Dalian Fugu Food Co.,Ltd.,Dalian 116400,China)
出处 《食品安全质量检测学报》 CAS 北大核心 2023年第22期143-151,共9页 Journal of Food Safety and Quality
基金 大连市“揭榜挂帅”计划项目(XLYC2002106) 大连市科技创新基金项目(2022JJ13SN090)。
关键词 哈维氏弧菌 荧光法 可视化环介导等温扩增技术 重组酶聚合酶扩增 Vibrio harveyi fluorescence visual loop-mediated isothermal amplification recombinase polymerase amplification
  • 相关文献

参考文献13

二级参考文献105

共引文献99

同被引文献44

引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部