摘要
为实现中欧空调制冷能效系数SEER之间的转化计算,本文以中欧能效标准规定的SEER定义式为基准计算式,提出利用标准计算中关于工况转化的分段插值方法,建立中欧测试参数的转换关系式,以此构建能效间的转化算法,实现了通过测试国标规定的5组工况,同时计算获得中欧SEER,经实验验证,该算法精度高达99.66%。
The conversion of seasonal cooling energy efficiency ratio(SEER)between China and Europe energy efficiency standards was investigated.The benchmark for this analysis was the definition equations specified in the respective standards.Piecewise interpolation methods were employed to facilitate the transformation of test parameters between the two national stand⁃ards.Utilizing this approach,an algorithm for converting SEER values between China and Europe standards was established.No⁃tably,the Europe SEER could be directly calculated by conducting tests under the 5 groups of working conditions stipulated in the China standard.Experimental verification demonstrates that the algorithm achieves a high level of accuracy with results reaching up to 99.66%.
作者
郑凯轩
李皖皖
蒋骏
王飞
Zheng Kaixuan;Li Wanwan;Jiang Jun;Wang Fei(Zhengzhou University of Industrial Technology,Zhengzhou 451100,China;Henan university of technology,Zhengzhou 450001,China;Qingdao Haier Air Conditioner Co.Ltd,Qindao 266103,China)
出处
《低温与超导》
CAS
北大核心
2023年第7期90-98,共9页
Cryogenics and Superconductivity
基金
河南省科技攻关项目(222102520030)
河南省粮油仓储建筑与安全重点实验室开放课题基金(2021KF-A03)资助。
关键词
季节能效比
中欧
能效
能效转化
空调器
SEER
China and Europe
Energy efficiency
Conversion
Air conditioner