摘要 为解决当前地铁车站空调系统水处理存在阻垢率低,水体富营养化现象严重的问题,开展地铁车站空调系统水处理方法分析研究。通过空调系统水迁移、空调系统水过滤,实现对水的初步处理。再通过阻垢缓蚀剂筛选、基于静态阻垢法的空调系统水处理,提升水的阻垢率,从而达到阻垢、缓蚀效果,促进地铁车站空调系统环境效益和经济效益的提升。 In order to solve the problems of low scale inhibition rate and severe eutrophication of water bodies in the current water treatment of subway station air conditioning systems,analysis and research on water treatment methods for subway station air conditioning systems have been carried out.Preliminary water treatment is achieved through water migration and filtration in the air conditioning system.Through the screening of scale and corrosion inhibitors,and the water treatment of the air conditioning system based on static scale inhibition method,the scale inhibition rate of the water is improved,thereby achieving scale and corrosion inhibition effects and promoting the improvement of environmental and economic benefits of the subway station air conditioning system.
作者 程有平 Cheng Youping(Wuhan Metro Operation Co.,Ltd.,Wuhan,China)
出处 《科学技术创新》 2023年第12期208-211,共4页 Scientific and Technological Innovation
关键词 地铁 空调 方法 水处理 系统 车站 subway air conditioner method water treatment system station