大口径弧形管道装配式制冷机房研究与应用

RESEARCH AND APPLICATION OF PREFABRICATED REFRIGERATION ROOM WITH LARGE-DIAMETER CURVED PIPE
下载PDF
导出
摘要 为响应国家号召,贯彻国家绿色建筑施工理念,北京工人体育场制冷机房采用装配式机房施工,同时结合机房弧形结构造型,采用国内首例大口径弧形管道装配式预制机房,总结相关工厂化预制及现场装配精度、质量控制要点,对整体装配进行效益分析。 In response to the national call and to implement the national green building construction concept,the refrigeration room of the Beijing Workers Stadium adopts a prefabricated construction and,at the same time,uses the first prefabricated machine room with large-diameter curved pipes by combining with the curved structure of the machine room.During this process,the relevant factory prefabrication,on-site assembly precision and quality control points are summarized and the benefit of the overall assembly is analyzed.
作者 曹美光 李健 李清亮 赵亚朋 党海彬 彭军军 CAO Mei-guang;LI Jian;LI Qing-liang;ZHAO Ya-peng;DANG Hai-bin;PENG Jun-jun(Beijing No.3 Construction Engineering Co.,Ltd.,100044,Beijing,China)
出处 《建筑技术》 2023年第5期528-531,共4页 Architecture Technology
关键词 装配式 弧形管道 误差控制 制冷机房 prefabricated type curved pipe error control refrigeration plant room