摘要
本文针对国内LNG接收站及外输金属管线持续增加的趋势,提出阴极保护技术是对站场内外埋地金属管道防腐的有效手段。通过依托项目进行分析,比较强制电流法和牺牲阳极法的优劣;进一步通过计算,得出牺牲阳极阴极保护所需要的工程量,对后续工程造价、工程施工及工程质量有实际的指导意义。
According to the increasing trend of LNG terminals and external metal pipelines in China, the cathodic protection technology is an effective means to protect against the buried metal pipelines inside and outside the station.By comparing the advantages of forced current method and sacrificial anode method, further calculate the quantities of sacrifice anode cathode protection, thus guiding the subsequent project cost, engineering construction and engineering quality.
作者
李龙焕
刘桂云
李贤才
劳锦洪
LI Long-huan;LIU Gui-yun;LI Xian-cai;LAO Jin-hong(Guangzhou City Construction College,Guangzhou 510627,China;Guangzhou Gas Group Co.,Ltd,Guangzhou 510625,China)
出处
《世界有色金属》
2022年第21期157-159,共3页
World Nonferrous Metals
基金
2021年度广东省教育厅科研平台和科研项目,大湾区持续增长杂散电流对大截面钢质管道生命周期影响研究,项目编号:21KTSCX353。
关键词
阴极保护
LNG接收站
金属管道
工程量计算
cathodic protection
LNG terminal
metal pipe
engineering quantity calculation