摘要
通过对水质特性与水垢和腐蚀产生原理分析,选择适合高级别生物安全实验室防护区用水种类。结果表明,自来水已不再满足高级别生物安全实验室用水需求,软水水质受当地自来水水质限制差别较大,反渗透水能够满足生物安全实验室的要求,对设备维保更有利。
Through the analysis of water quality characteristics and the principle of scale and corrosion generation,choosing the kind of water that is more suitable for protective zone of high-level biosafety laboratories.The results show that tap water no longer meets the water demand of high-level biosafety laboratories,and the quality of soft water is limited by the quality of local tap water,which varies greatly from place to place.The reverse osmosis water can meet the requirements of biosafety laboratories and is more beneficial to equipment maintenance.
作者
薛森仁
董践潇
王博骏
胡洋
易洪敏
林静雯
XUE Sen-ren;DONG Jian-xiao;WANG Bo-jun;HU Yang;YI Hong-min;LIN Jing-wen(Biosafety Laboratory of West China Hospital,Sichuan University,Chengdu 610041,China;China State Construction Engineering Corporation,Beijing 100013,China)
出处
《应用化工》
CAS
CSCD
北大核心
2022年第12期3694-3696,3701,共4页
Applied Chemical Industry
基金
四川省科技计划项目(重点研发项目)(2021YFS0403)。
关键词
高级别生物安全实验室
水垢
水质
反渗透水
high-level biosafety laboratory
scale
water quality
reverse osmosis water