摘要 自2020年新型冠状病毒肺炎疫情爆发以来,医院负压留观病房对阻断病毒传播起到了至关重要的作用。负压留观病房建设中暖通专业的重点主要有系统形式、压差控制、气流组织、控制措施等。本文主要从以上重点切入,结合后期施工时发现的具体问题做出经验总结,供类似项目的前期设计参考。 Since the outbreak of COVID-19 pandemic in 2020,hospital negative-pressure retention wards have been pivotal in the fight against the virus.The key points of heating,ventilation and air conditioning(HVAC)for the negative-pressure retention wards include:system form,pressure differential control,airflow organization,control measures.Based on the above issues,combined with specific problems existing during the construction phrase,this paper summarizes the experiences and knowledge,providing reference for preliminary design of similar projects.
作者 冯腾元 王员兴 Feng Teng-yuan;Wang Yuan-xing(Hangzhou Hospital of Traditional Chinese Medicine,Hangzhou 310051,Zhejiang Province,China)
机构地区 杭州市中医院
出处 《建筑与装饰》 2022年第18期75-78,共4页 Construction & Decoration
关键词 新型冠状病毒肺炎疫情 负压留观病房 空调通风 COVID-19 pandemic negative-pressure retention ward air conditioning ventilation