摘要
本文从目前10KV及以下绝缘导线接头方式(含终端接头、中间接续接头、跳线分流等)存在的隐患现象和危害性作出系统性的总结分析,并最后提出一种全新的从使用质量和通用方便角度的解决方法,从而间接降低电网公司线路改造成本,提升系统线路使用质量。
This paper systematically summarizes and analyzes the hidden dangers and hazards of the current 10kV and below insulated conductor joint modes(including terminal joint,intermediate joint,jumper shunt,etc.),and finally puts forward a new solution from the perspective of use quality and general convenience,so as to indirectly reduce the line reconstruction cost of power grid company,Improve the service quality of system lines.
作者
邵源鹏
Shao Yuanpeng(Guangzhou Panyu Cable Group Co.,Ltd,Guangzhou Guangdong,510000)
出处
《电子测试》
2022年第12期96-98,共3页
Electronic Test
关键词
10KV及以下绝缘导线
通用
绝缘导线通用连接装置
10kV and below insulated conductor
General
Universal connecting device for insulated conductor