摘要
阐述了Maquet Flow-i麻醉机稳定运行的重要性,结合麻醉机气路结构的工作原理,详细分析了该款麻醉机的4例气路部分的典型故障,并给出了具体的故障分析思路、排除方法以及检查维护与清洁消毒的操作要点,为同行分析和处理类似故障提供了参考。
The importance of the stable operation of Maquet Flow-i anesthesia machine was described.Based on the working principle and gas path structure of Maquet Flow-i anesthesia machine four typical faults in the gas path were analyzed,then the idea and method for treating the faults and the key points for inspection,maintenance,cleaning and disinfection were put forward.References were provided for analyzing and treating similar faults.
作者
陈红
郭大为
刘林
乔辉
CHEN Hong;GUO Da-wei;LIU Lin;QIAO Hui(Operation Room,Beijing Shijitan Hospital of Capital Medical University,Beijing 100038,China;Department of Clinical Engineering,Beijing Shijitan Hospital of Capital Medical University,Beijing 100038,China)
出处
《医疗卫生装备》
CAS
2022年第5期98-100,103,共4页
Chinese Medical Equipment Journal